I've just installed 1.3.9rc14 on a fresh switch out a box.

Getting this in the system logs. There is currently nothing plugged into the switch. Should I be worried about this?


Dec 31 19:32:31 switch[1358]: 48V is out of range (41.4V)
Dec 31 19:32:31 switch[1358]: 24V is out of range (20.2V)
Dec 31 19:32:31 switch[1358]: 24V (Ports 13-24) is out of range (20.2V)
Dec 31 19:32:31 switch[1358]: 3V is out of range (2.3V)

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-24-400A voltage out of range

Mon Jan 18, 2016 4:00 pm

mayheart wrote:I've just installed 1.3.9rc14 on a fresh switch out a box.

Getting this in the system logs. There is currently nothing plugged into the switch. Should I be worried about this?


Dec 31 19:32:31 switch[1358]: 48V is out of range (41.4V)
Dec 31 19:32:31 switch[1358]: 24V is out of range (20.2V)
Dec 31 19:32:31 switch[1358]: 24V (Ports 13-24) is out of range (20.2V)
Dec 31 19:32:31 switch[1358]: 3V is out of range (2.3V)


Do you have an SFP module in?
If so remove it and see what happens as some SFP modules are incompatible or your SFP module is bad. (THIS IS MY GUESS)

If not try the upgrade again and then power cycle it.

If it is still acting acting up post up the Devices/Status Tab
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
mayheart
Experienced Member
 
Posts: 166
Joined: Thu Jan 15, 2015 1:42 pm
Location: Canada
Has thanked: 43 times
Been thanked: 40 times

Re: WS-24-400A voltage out of range

Tue Jan 19, 2016 1:27 pm

It looks SFP related indeed. I had another switch that has a SFP in it. was running 1.1.8 [yeah I know old firmware ;) ] after upgrading it to 1.3.9rc14 I'm getting the same problem. I've reflashed the unit and cycled it. Everything is working though, including the fiber port.

One unit is using Cisco SFPs, this one is using Telecoast.

Dec 31 19:00:44 switch[1462]: Detected warm boot
Dec 31 19:00:47 switch[1407]: 48V is out of range (12.9V)
Dec 31 19:00:47 switch[1407]: 24V is out of range (6.0V)
Dec 31 19:00:47 switch[1407]: 3V is out of range (1.3V)
Dec 31 19:00:47 switch[1407]: Port 1: PoE is enabled and port has link, power should not be 0
Dec 31 19:00:47 switch[1407]: Port 2: PoE is enabled and port has link, power should not be 0

Image


Image

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-24-400A voltage out of range

Tue Jan 19, 2016 2:20 pm

Yes that is more than likely an incompatible or BAD SFP module.

You're going to have to try a different module.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

Return to Hardware and software issues

Who is online

Users browsing this forum: Bing [Bot], Google [Bot] and 63 guests