Re: v1.3.9 FINAL bug reports and comments

Mon Feb 08, 2016 4:11 pm

Updated three 8AC and one 24AC switches from 1.3.8 to 1.3.9. The latter failed to start snmpd upon reboot. Restarted.
One difference noted is that the switches can no longer maintain an SNMP query frequency of 5 sec. from PRTG for single port throughput value. Have to dial it back to 10 sec.

User avatar
Eric Stern
Employee
Employee
 
Posts: 532
Joined: Wed Apr 09, 2014 9:41 pm
Location: Toronto, Ontario
Has thanked: 0 time
Been thanked: 130 times

Re: v1.3.9 FINAL bug reports and comments

Tue Feb 09, 2016 12:15 pm

RebusCom wrote:Updated three 8AC and one 24AC switches from 1.3.8 to 1.3.9. The latter failed to start snmpd upon reboot. Restarted.
One difference noted is that the switches can no longer maintain an SNMP query frequency of 5 sec. from PRTG for single port throughput value. Have to dial it back to 10 sec.


Check to make sure you are using SNMP v2c. On a 24 port using v1 a walk takes almost 5 seconds. Using v2c it is less than 1 second.

User avatar
canpandave
Member
 
Posts: 45
Joined: Thu Mar 26, 2015 6:28 pm
Location: Edmonton, AB CANADA
Has thanked: 0 time
Been thanked: 4 times

Re: v1.3.9 FINAL bug reports and comments

Wed Feb 10, 2016 9:35 am

Upgraded all switches to 1.3.9, no issues although as a precaution, I rebooted each switch first.

User avatar
mhoppes
Associate
Associate
 
Posts: 664
Joined: Thu Apr 10, 2014 9:14 pm
Location: Pennsylvania
Has thanked: 10 times
Been thanked: 125 times

Re: v1.3.9 FINAL bug reports and comments

Wed Feb 10, 2016 4:16 pm

Happy with 1.3.9 here as well. Handful of switches upgraded successfully.

User avatar
RebusCom
Experienced Member
 
Posts: 111
Joined: Sun Nov 30, 2014 9:42 pm
Location: Washington
Has thanked: 13 times
Been thanked: 11 times

Re: v1.3.9 FINAL bug reports and comments

Thu Feb 11, 2016 9:01 am

Eric Stern wrote:
RebusCom wrote:Updated three 8AC and one 24AC switches from 1.3.8 to 1.3.9. The latter failed to start snmpd upon reboot. Restarted.
One difference noted is that the switches can no longer maintain an SNMP query frequency of 5 sec. from PRTG for single port throughput value. Have to dial it back to 10 sec.


Check to make sure you are using SNMP v2c. On a 24 port using v1 a walk takes almost 5 seconds. Using v2c it is less than 1 second.


This is with v2. V1 doesn't work.

User avatar
Eric Stern
Employee
Employee
 
Posts: 532
Joined: Wed Apr 09, 2014 9:41 pm
Location: Toronto, Ontario
Has thanked: 0 time
Been thanked: 130 times

Re: v1.3.9 FINAL bug reports and comments

Thu Feb 11, 2016 4:31 pm

RebusCom wrote:Updated three 8AC and one 24AC switches from 1.3.8 to 1.3.9. The latter failed to start snmpd upon reboot. Restarted.
One difference noted is that the switches can no longer maintain an SNMP query frequency of 5 sec. from PRTG for single port throughput value. Have to dial it back to 10 sec.


How do you have the sensor configured in PRTG? It won't even let me set it to 5 seconds.

User avatar
iellison
 
Posts: 16
Joined: Wed Apr 01, 2015 3:04 pm
Has thanked: 3 times
Been thanked: 8 times

Re: v1.3.9 FINAL bug reports and comments

Thu Feb 11, 2016 7:21 pm

Not sure what the issue is, but reporting it here. WS-12-250-A running 1.3.9. We are doing some Cambium ePMP testing on a tower with UBNT clients (swapped out Rocket M2 AP's for ePMP). During the change, we are running the ePMP in WiFi mode while we swap out CPE's. Our customer internet traffic is tagged to VLAN 300 on the UBNT CPE (wlan0 in bridge1, lan0 and wlan0.300 in bridge2), bridge mode.

CPE's connect to the AP's, but no VLAN traffic was making it to the switch (nothing in MAC table). We found this strange because we bench tested this configuration in the shop to ensure it would work in the field. The only difference in the field was have a switch between the router and the AP's.

Long story short, we rolled back the firmware to 1.3.8, and everything is working now. We tried rebooting the switch, and verified all configs before rolling back. Granted this is not an everyday set of circumstances, but thought I would pass along the data anyway.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.3.9 FINAL bug reports and comments

Thu Feb 11, 2016 8:52 pm

iellison wrote:Not sure what the issue is, but reporting it here. WS-12-250-A running 1.3.9. We are doing some Cambium ePMP testing on a tower with UBNT clients (swapped out Rocket M2 AP's for ePMP). During the change, we are running the ePMP in WiFi mode while we swap out CPE's. Our customer internet traffic is tagged to VLAN 300 on the UBNT CPE (wlan0 in bridge1, lan0 and wlan0.300 in bridge2), bridge mode.

CPE's connect to the AP's, but no VLAN traffic was making it to the switch (nothing in MAC table). We found this strange because we bench tested this configuration in the shop to ensure it would work in the field. The only difference in the field was have a switch between the router and the AP's.

Long story short, we rolled back the firmware to 1.3.8, and everything is working now. We tried rebooting the switch, and verified all configs before rolling back. Granted this is not an everyday set of circumstances, but thought I would pass along the data anyway.


Would be real curious for you to bench test this with a switch and see what it takes to make it work as there should be no difference between v1.3.8 and v1.3.9 in regard to this.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
RebusCom
Experienced Member
 
Posts: 111
Joined: Sun Nov 30, 2014 9:42 pm
Location: Washington
Has thanked: 13 times
Been thanked: 11 times

Re: v1.3.9 FINAL bug reports and comments

Thu Feb 11, 2016 10:04 pm

Eric Stern wrote:
RebusCom wrote:Updated three 8AC and one 24AC switches from 1.3.8 to 1.3.9. The latter failed to start snmpd upon reboot. Restarted.
One difference noted is that the switches can no longer maintain an SNMP query frequency of 5 sec. from PRTG for single port throughput value. Have to dial it back to 10 sec.


How do you have the sensor configured in PRTG? It won't even let me set it to 5 seconds.


Extras, Options, Tweaks
PRTG Traffic Grapher Prof. Edition

User avatar
Eric Stern
Employee
Employee
 
Posts: 532
Joined: Wed Apr 09, 2014 9:41 pm
Location: Toronto, Ontario
Has thanked: 0 time
Been thanked: 130 times

Re: v1.3.9 FINAL bug reports and comments

Fri Feb 12, 2016 6:47 pm

Ok, I got it set to 5s. It seems to work ok. What kind of errors/problems are you seeing?

BTW, I did notice a note in PRTG that says anything less than 10 seconds may not work and is not officially supported.