New-just-out-of-the-box WS-12-250-DC switch w/ v1.3.8 (purchased from a distributor) shows board voltage reading errors. No POE enabled on any port.
Tried upgrading to v.1.3.9 with no change....factory reset with no change...downgrade to v1.3.8 and still no change.
RMA time?
WS-12-250-DC Board Voltage errors
-
lligetfa - Associate
- Posts: 1191
- Joined: Sun Aug 03, 2014 12:12 pm
- Location: Fort Frances Ont. Canada
- Has thanked: 307 times
- Been thanked: 381 times
Re: WS-12-250-DC Board Voltage errors
Are there any SFPs plugged into the switch? Is this being bench tested or at a tower site? If tower site is it near a high power FM transmitter?
- bgoode
- Member
- Posts: 21
- Joined: Tue Jul 21, 2015 12:20 pm
- Location: AZ USA
- Has thanked: 1 time
- Been thanked: 2 times
Re: WS-12-250-DC Board Voltage errors
No SFP's and it on the bench in the office....
-
Dave - Employee
- Posts: 726
- Joined: Tue Apr 08, 2014 6:28 pm
- Has thanked: 1 time
- Been thanked: 158 times
Re: WS-12-250-DC Board Voltage errors
weird...can you post a screen shot of entire status page?
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: WS-12-250-DC Board Voltage errors
We hand test each unit several times before we ship, really hard to believe it would do that out of the box?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
- bgoode
- Member
- Posts: 21
- Joined: Tue Jul 21, 2015 12:20 pm
- Location: AZ USA
- Has thanked: 1 time
- Been thanked: 2 times
Re: WS-12-250-DC Board Voltage errors
Also noticed the Power Supply Efficiency bar is showing red and >85%. Other WS-12-250-DC switches in production with the same voltage input of 23.8v show efficiency at >92% in the green.
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: WS-12-250-DC Board Voltage errors
RMA it back for us to examine: viewtopic.php?f=6&t=1259
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
7 posts
Page 1 of 1
Who is online
Users browsing this forum: No registered users and 77 guests