v1.4.0rc1-16 Bug reports and comments
- IntL-Daniel
- Experienced Member
- Posts: 170
- Joined: Mon Nov 02, 2015 5:07 pm
- Location: Czech Republic
- Has thanked: 7 times
- Been thanked: 9 times
Re: v1.4.0rcX Bug reports and comments
Hi Chris, thanks for another release. Did anybody read my posts above about false undervoltage detections on WS-12-250-AC and AF24 cable measurement issue? I had to roll back to 1.3.9 and false detections disappeared at all.
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: v1.4.0rcX Bug reports and comments
IntL-Daniel wrote:Hi Chris, thanks for another release. Did anybody read my posts above about false undervoltage detections on WS-12-250-AC and AF24 cable measurement issue? I had to roll back to 1.3.9 and false detections disappeared at all.
Try rc12 and see if we fixed that - it should?
If not let me know
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
lligetfa - Associate
- Posts: 1191
- Joined: Sun Aug 03, 2014 12:12 pm
- Location: Fort Frances Ont. Canada
- Has thanked: 307 times
- Been thanked: 381 times
Re: v1.4.0rcX Bug reports and comments
sirhc wrote:Try rc12 and see if we fixed that - it should?
If not let me know
Did I miss the memo as to where you hid rc12?
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: v1.4.0rcX Bug reports and comments
OUCH - Sorry for the missed character - FIXED
The other things were correct and the link downloads rc12
The other things were correct and the link downloads rc12
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
lligetfa - Associate
- Posts: 1191
- Joined: Sun Aug 03, 2014 12:12 pm
- Location: Fort Frances Ont. Canada
- Has thanked: 307 times
- Been thanked: 381 times
Re: v1.4.0rcX Bug reports and comments
Hidden in the fine print. I have old eyes.
RC12 installed fine.
RC12 installed fine.
- IntL-Daniel
- Experienced Member
- Posts: 170
- Joined: Mon Nov 02, 2015 5:07 pm
- Location: Czech Republic
- Has thanked: 7 times
- Been thanked: 9 times
Re: v1.4.0rcX Bug reports and comments
sirhc wrote:IntL-Daniel wrote:Hi Chris, thanks for another release. Did anybody read my posts above about false undervoltage detections on WS-12-250-AC and AF24 cable measurement issue? I had to roll back to 1.3.9 and false detections disappeared at all.
Try rc12 and see if we fixed that - it should?
If not let me know
So there was something done about that? Not mentioned in the changelog...
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: v1.4.0rcX Bug reports and comments
A lot was done in the "engine" of the code pertaining to I2C which would cover that.
We NEED to get v1.4.0 finalized SOON because as it is there will be shortages of stock soon as we had to hold up production as the design changed on the WS-12-MINI board to fix "hopefully" the FM Tower issue with the DC switches.
This will affect WS-12-DC, WS-12-250-AC, WS-12-250-DC, WS-12-DC models.
WS-10-250-AC will also get crunched.
The new boards coming out will require v1.4.0 so we can not make them until then.
This delay also held up the production batch after this one so things are going to get tight soon.
Possible Shortage alert by the end of this month as supplies are running low.
As it is sales have grown by several hundred percent for each month this year and keep in mind we have to place orders 8 weeks in advance and then this happened that caused production to hold up waiting on hardware and software changes to happen for the SMART DC models with FM Towers. And since the AC and DC share the same boards and the several models such as the WS-10-250-AC, WS-12-250-AC, WS-12-400-AC, WS-12-250-DC, and WS-12-DC all use the same PCB well bad things happen when you want to change the design.
Now to help offset this:
the WS-8-150-AC will be out but the kits are sitting at the assembler house waiting on v1.4.0 final as it requires it too.
the WS-6-150-DC will be out but the kits are sitting at the assembler house waiting on v1.4.0 final as it requires it too.
We NEED to get v1.4.0 finalized SOON because as it is there will be shortages of stock soon as we had to hold up production as the design changed on the WS-12-MINI board to fix "hopefully" the FM Tower issue with the DC switches.
This will affect WS-12-DC, WS-12-250-AC, WS-12-250-DC, WS-12-DC models.
WS-10-250-AC will also get crunched.
The new boards coming out will require v1.4.0 so we can not make them until then.
This delay also held up the production batch after this one so things are going to get tight soon.
Possible Shortage alert by the end of this month as supplies are running low.
As it is sales have grown by several hundred percent for each month this year and keep in mind we have to place orders 8 weeks in advance and then this happened that caused production to hold up waiting on hardware and software changes to happen for the SMART DC models with FM Towers. And since the AC and DC share the same boards and the several models such as the WS-10-250-AC, WS-12-250-AC, WS-12-400-AC, WS-12-250-DC, and WS-12-DC all use the same PCB well bad things happen when you want to change the design.
Now to help offset this:
the WS-8-150-AC will be out but the kits are sitting at the assembler house waiting on v1.4.0 final as it requires it too.
the WS-6-150-DC will be out but the kits are sitting at the assembler house waiting on v1.4.0 final as it requires it too.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
Mikea - Associate
- Posts: 112
- Joined: Fri Jun 26, 2015 6:22 am
- Location: Korinthos (Greece)
- Has thanked: 21 times
- Been thanked: 31 times
Re: v1.4.0rcX Bug reports and comments
I m confident that you and the Team will nail this once again!
Keep up with your great work!
Keep up with your great work!
Mike A - www.iwisp.gr
- IntL-Daniel
- Experienced Member
- Posts: 170
- Joined: Mon Nov 02, 2015 5:07 pm
- Location: Czech Republic
- Has thanked: 7 times
- Been thanked: 9 times
Re: v1.4.0rcX Bug reports and comments
sirhc wrote:I do not believe we changed the temp threshold between v1.3.9 and v1.4.0.
Your board is running at 53C which would ask the fan to be running at almost max speed.
What is the room temperature where this is installed?
You could always downgrade to v1.3.9 and see what it does and reports then.
Hi Chris, just want to inform that this "case" was solved by reconfiguration of aircon and hw changes of our protection box for the switch there (more wholes for airflow). Currently we have board temp at ~50 and fan is stable at ~6500-7000rpm.
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: v1.4.0rcX Bug reports and comments
Make sure Ladybugs can not get in boxes. Had an RMA recently that was dead Ladybug guts shorting out board.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Who is online
Users browsing this forum: No registered users and 63 guests