Airfiber 24 drawing high current off ws-24-400b

User avatar
redpeppers
Member
 
Posts: 15
Joined: Sat Jan 16, 2016 4:56 pm
Location: Lebanon, MO
Has thanked: 1 time
Been thanked: 0 time

Airfiber 24 drawing high current off ws-24-400b

Fri Apr 29, 2016 6:46 pm

I have two airfiber24 radios, one in eth1 and one in eth2 (both configured for 48VH) on a ws-24-400b. According to the netonix GUI the AF24 that is plugged into Ether1 is drawing ~55 watts but the AF24 in ether2 is drawing ~82 watts. Could this be a cable issue? The link is up but obviously I don't want to leave it like this because it seems that it is exceeding the rated output power of the netonix interface.

User avatar
sirhc
Employee
Employee
 
Posts: 7421
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: Airfiber 24 drawing high current off ws-24-400b

Fri Apr 29, 2016 7:00 pm

What firmware version? Upgrade if not v1.3.9 and reboot just for giggles.

55 watts is not far off but 80+ watts - WOW

Yea that seems wrong, real wrong.

Possible causes:
Bad current sensors -possible
Damaged current sensors - possible
Damaged radio pulling to much power. - Doubtful

82 watts is exceeding the port rating so if it is correct failure is very probable.

I would investigate.

You could swap the ports and see if the ratings follow.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
redpeppers
Member
 
Posts: 15
Joined: Sat Jan 16, 2016 4:56 pm
Location: Lebanon, MO
Has thanked: 1 time
Been thanked: 0 time

Re: Airfiber 24 drawing high current off ws-24-400b

Fri Apr 29, 2016 7:04 pm

Firmware is 1.3.9.

I will eliminate the port being a problem by switching to another interface. It appears that only ether1 and ether2 have 48VH correct?

User avatar
sirhc
Employee
Employee
 
Posts: 7421
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: Airfiber 24 drawing high current off ws-24-400b

Fri Apr 29, 2016 7:37 pm

redpeppers wrote:Firmware is 1.3.9.

I will eliminate the port being a problem by switching to another interface. It appears that only ether1 and ether2 have 48VH correct?


Yes the 400B only offers 48VH on ports 1 and 2

Do not try and power AF24 on normal 48V ports
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
redpeppers
Member
 
Posts: 15
Joined: Sat Jan 16, 2016 4:56 pm
Location: Lebanon, MO
Has thanked: 1 time
Been thanked: 0 time

Re: Airfiber 24 drawing high current off ws-24-400b

Wed May 18, 2016 5:56 pm

ok so with nothing even plugged into ether2 on the netonix switch it still shows a wattage draw of 40~ watts. What do you think?

User avatar
sirhc
Employee
Employee
 
Posts: 7421
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: Airfiber 24 drawing high current off ws-24-400b

Wed May 18, 2016 6:02 pm

Sounds like the current sensors are damaged?

This occurs from the components being exposed to voltage > 60V which would be from ESD or ground potential shift.

Read the grounding posts on good grounding practices.

viewtopic.php?f=30&t=188
viewtopic.php?f=30&t=1429
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
redpeppers
Member
 
Posts: 15
Joined: Sat Jan 16, 2016 4:56 pm
Location: Lebanon, MO
Has thanked: 1 time
Been thanked: 0 time

Re: Airfiber 24 drawing high current off ws-24-400b

Wed May 18, 2016 6:05 pm

It was like this right out of the box. I first posted it the night i installed it.

User avatar
sirhc
Employee
Employee
 
Posts: 7421
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: Airfiber 24 drawing high current off ws-24-400b

Wed May 18, 2016 6:09 pm

redpeppers wrote:It was like this right out of the box. I first posted it the night i installed it.


I guess it is possible but we do check the current sensors before we serialize them?

If they were damaged it is easy to spot as they look like picture 4 and or 5 of this post, they are what most blow current sensors look like which does not just happen on its own.
viewtopic.php?f=17&t=1697#p12743

Either way read this post on how to RMA it and it also shows you how we test each switch before we assign the MAC address.
viewtopic.php?f=6&t=1259
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

Return to General Discussion

Who is online

Users browsing this forum: No registered users and 79 guests