AC switches ground connected to PoE pins 7,8?

User avatar
wisphopefull
Member
 
Posts: 36
Joined: Mon Aug 04, 2014 2:50 pm
Has thanked: 5 times
Been thanked: 3 times

AC switches ground connected to PoE pins 7,8?

Thu May 19, 2016 9:51 pm

So I just ordered my first Netonix switch (WS-10-250-AC) and it's on the way and was wondering if the Netonix AC switches AC ground pin is also connected to pins7,8?

I discovered almost 3 years ago on UBNT forum that ToughSwitch 8 Pro had the ground pin connected to pins 7,8 (negative) , but not the PoE adapters.
eejimm:

the AC neutral pin on the 8-port TS-Pro is connected to pins 7,8 and the RJ-45 ground

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: AC switches ground connected to PoE pins 7,8?

Thu May 19, 2016 10:35 pm

our AC ground is not tied to our POE ground...

User avatar
wisphopefull
Member
 
Posts: 36
Joined: Mon Aug 04, 2014 2:50 pm
Has thanked: 5 times
Been thanked: 3 times

Re: AC switches ground connected to PoE pins 7,8?

Fri May 20, 2016 12:12 am

Dave wrote:our AC ground is not tied to our POE ground...

When you say PoE ground you mean the RJ45 shield?

If so I asked Chris that before and he said the RJ45 shield is connected and grounded through AC cord ground (same as Toughswitch Pro)
viewtopic.php?f=6&t=1189&p=8866#p8866

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: AC switches ground connected to PoE pins 7,8?

Fri May 20, 2016 7:24 am

When you say PoE ground you mean the RJ45 shield?


The AC ground is connected to the RJ45 connector shield, which is not the same as the POE power ground pins 7 & 8.

User avatar
wisphopefull
Member
 
Posts: 36
Joined: Mon Aug 04, 2014 2:50 pm
Has thanked: 5 times
Been thanked: 3 times

Re: AC switches ground connected to PoE pins 7,8?

Fri May 20, 2016 10:09 am

Thanks Dave

User avatar
wisphopefull
Member
 
Posts: 36
Joined: Mon Aug 04, 2014 2:50 pm
Has thanked: 5 times
Been thanked: 3 times

Re: AC switches ground connected to PoE pins 7,8?

Fri May 20, 2016 10:59 am

by the way is the grounding lug on the case connected to the AC ground or pins 7,8?

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: AC switches ground connected to PoE pins 7,8?

Fri May 20, 2016 11:06 am

ac ground

User avatar
sirhc
Employee
Employee
 
Posts: 7421
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: AC switches ground connected to PoE pins 7,8?

Fri May 20, 2016 11:32 am

On AC switch models the lug is more for added safety in case the user is touching the chassis when an ESD or strike occurs but with the DC models it is imperative that you hook it up and that the ground in your box is bonded to the tower ground. You should also have a dedicated ground run to your radios that is less resistance and shorter path to earth ground than your Ethernet cables.

Do not use wire or connectors that are too large as you may pull the lug from the chassis.
10 AWG is really too big, 12 AWG and a crimp end is preferred


Read these posts on grounding practices:
viewtopic.php?f=30&t=188
viewtopic.php?f=30&t=1429
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

Return to General Discussion

Who is online

Users browsing this forum: Bing [Bot] and 70 guests