Error message in log

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
tomtech
Member
 
Posts: 15
Joined: Wed Sep 09, 2015 1:27 am
Location: San Fernando, CA
Has thanked: 0 time
Been thanked: 2 times

Error message in log

Thu May 26, 2016 12:42 pm

Hi
We have a WS-6 mini. Two ethernet connections, one POE at 24v, and the unit is powered by a Ubiquiti injector on port 1, no data on port 1.
last night got this message:

May 26 09:32:18 switch[1252]: 3V is out of range (3.1V)

Should i be concerned? No errors on any port.
Let me know. Any thoughts are helpful.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Error message in log

Thu May 26, 2016 12:57 pm

No, not a real problem

What firmware version are you running, always report firmware version when reporting an issue?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
tomtech
Member
 
Posts: 15
Joined: Wed Sep 09, 2015 1:27 am
Location: San Fernando, CA
Has thanked: 0 time
Been thanked: 2 times

Re: Error message in log

Thu May 26, 2016 1:01 pm

Sorry, I forgot to put in the firmware. Just upgraded three days ago to 1.4.0

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Error message in log

Thu May 26, 2016 1:04 pm

tomtech wrote:Sorry, I forgot to put in the firmware. Just upgraded three days ago to 1.4.0


hmmm, then that should not have generated an error at 3.1V, will push this up to Dave and Eric
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
tomtech
Member
 
Posts: 15
Joined: Wed Sep 09, 2015 1:27 am
Location: San Fernando, CA
Has thanked: 0 time
Been thanked: 2 times

Re: Error message in log

Thu May 26, 2016 1:49 pm

Screen shot of status page and log output for the last day or so attached. Hope this helps. the 24v peaks over 25v and turns red every 5/10 seconds or so.
STP: set port 6 to forwarding
May 24 18:13:51 STP: set port 6 to discarding
May 24 18:13:51 STP: set port 6 to learning
May 24 18:13:51 STP: set port 6 to forwarding
May 24 18:16:28 STP: set port 6 to discarding
May 24 18:16:28 STP: set port 6 to learning
May 24 18:16:28 STP: set port 6 to forwarding
May 24 18:16:53 STP: set port 6 to discarding
May 24 18:16:54 STP: set port 6 to learning
May 24 18:16:54 STP: set port 6 to forwarding
May 24 18:23:50 STP: set port 6 to discarding
May 24 18:23:50 STP: set port 6 to learning
May 24 18:23:50 STP: set port 6 to forwarding
May 25 00:48:51 STP: set port 6 to discarding
May 25 00:48:51 STP: set port 6 to learning
May 25 00:48:51 STP: set port 6 to forwarding
May 25 10:42:51 STP: set port 6 to discarding
May 25 10:42:52 STP: set port 6 to learning
May 25 10:42:52 STP: set port 6 to forwarding
May 25 12:50:40 STP: set port 6 to discarding
May 25 12:50:42 STP: set port 6 to learning
May 25 12:50:43 STP: set port 6 to forwarding
May 25 14:11:51 STP: set port 6 to discarding
May 25 14:11:51 STP: set port 6 to learning
May 25 14:11:51 STP: set port 6 to forwarding
May 25 15:02:27 Port: link state changed to 'down' on port 3
May 25 15:02:27 STP: set port 3 to discarding
May 25 15:02:34 Port: link state changed to 'up' (100M-H) on port 3
May 25 15:02:34 STP: set port 3 to discarding
May 25 15:02:53 STP: set port 3 to learning
May 25 15:02:53 STP: set port 3 to forwarding
May 25 15:03:12 Port: link state changed to 'down' on port 3
May 25 15:03:12 STP: set port 3 to discarding
May 25 15:03:13 Port: link state changed to 'up' (100M-F) on port 3
May 25 15:03:13 STP: set port 3 to discarding
May 25 15:03:16 STP: set port 3 to learning
May 25 15:03:16 STP: set port 3 to forwarding
May 25 15:03:57 Port: link state changed to 'down' on port 3
May 25 15:03:57 STP: set port 3 to discarding
May 25 15:04:04 Port: link state changed to 'up' (100M-F) on port 3
May 25 15:04:04 STP: set port 3 to discarding
May 25 15:04:06 STP: set port 3 to learning
May 25 15:04:06 STP: set port 3 to forwarding
May 25 15:35:50 Port: link state changed to 'down' on port 3
May 25 15:35:50 STP: set port 3 to discarding
May 25 15:38:25 Port: link state changed to 'up' (100M-F) on port 3
May 25 15:38:25 STP: set port 3 to discarding
May 25 15:38:28 STP: set port 3 to learning
May 25 15:38:28 STP: set port 3 to forwarding
May 25 15:39:11 Port: link state changed to 'down' on port 3
May 25 15:39:11 STP: set port 3 to discarding
May 25 15:39:17 Port: link state changed to 'up' (100M-F) on port 3
May 25 15:39:17 STP: set port 3 to discarding
May 25 15:39:20 STP: set port 3 to learning
May 25 15:39:20 STP: set port 3 to forwarding
May 25 15:42:17 Port: link state changed to 'down' on port 3
May 25 15:42:17 STP: set port 3 to discarding
May 25 15:44:45 Port: link state changed to 'up' (100M-F) on port 3
May 25 15:44:45 STP: set port 3 to discarding
May 25 15:44:48 STP: set port 3 to learning
May 25 15:44:48 STP: set port 3 to forwarding
May 25 15:45:47 Port: link state changed to 'down' on port 3
May 25 15:45:47 STP: set port 3 to discarding
May 25 15:45:53 Port: link state changed to 'up' (100M-F) on port 3
May 25 15:45:53 STP: set port 3 to discarding
May 25 15:45:56 STP: set port 3 to learning
May 25 15:45:56 STP: set port 3 to forwarding
May 25 17:46:54 STP: set port 6 to discarding
May 25 17:46:56 STP: set port 6 to learning
May 25 17:46:56 STP: set port 6 to forwarding
May 25 18:05:52 STP: set port 6 to discarding
May 25 18:05:53 STP: set port 6 to learning
May 25 18:05:53 STP: set port 6 to forwarding
May 25 18:16:51 STP: set port 6 to discarding
May 25 18:16:52 STP: set port 6 to learning
May 25 18:16:52 STP: set port 6 to forwarding
May 25 19:17:54 STP: set port 6 to discarding
May 25 19:17:54 STP: set port 6 to learning
May 25 19:17:54 STP: set port 6 to forwarding
May 25 19:19:53 STP: set port 6 to discarding
May 25 19:19:54 STP: set port 6 to learning
May 25 19:19:54 STP: set port 6 to forwarding
May 25 19:32:52 STP: set port 6 to discarding
May 25 19:32:53 STP: set port 6 to learning
May 25 19:32:53 STP: set port 6 to forwarding
May 25 19:37:51 STP: set port 6 to discarding
May 25 19:37:53 STP: set port 6 to learning
May 25 19:37:53 STP: set port 6 to forwarding
May 25 19:49:53 STP: set port 6 to discarding
May 25 19:49:54 STP: set port 6 to learning
May 25 19:49:54 STP: set port 6 to forwarding
May 25 19:53:53 STP: set port 6 to discarding
May 25 19:53:54 STP: set port 6 to learning
May 25 19:53:54 STP: set port 6 to forwarding
May 26 03:24:54 STP: set port 6 to discarding
May 26 03:24:54 STP: set port 6 to learning
May 26 03:24:54 STP: set port 6 to forwarding
May 26 06:06:53 STP: set port 6 to discarding
May 26 06:06:53 STP: set port 6 to learning
May 26 06:06:53 STP: set port 6 to forwarding
May 26 09:32:18 switch[1252]: 3V is out of range (3.1V)

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Error message in log

Thu May 26, 2016 2:18 pm

Your voltages are fine, we need to increase the valid range in the next firmware release slightly.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

Return to Hardware and software issues

Who is online

Users browsing this forum: No registered users and 52 guests