LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWITCHES

User avatar
Dawizman
Experienced Member
 
Posts: 141
Joined: Fri Jul 03, 2015 4:11 pm
Location: Cold Lake, AB - CANADA
Has thanked: 15 times
Been thanked: 22 times

Re: LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWIT

Tue May 31, 2016 9:31 pm

ozmetaldrummer wrote:Ubiquiti Powerbridge M10 ??


Yep. 24V just like all the other airmax M products.

colinhowlin
Member
 
Posts: 46
Joined: Wed Feb 17, 2016 10:00 am
Location: Ireland
Has thanked: 2 times
Been thanked: 2 times

Re: LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWIT

Wed Jun 01, 2016 8:51 am

SIAE AlfoPlus 17GHz works at 48VH.
Pulls around 35W at load.

We were powering these with an AirFiber power supply.

User avatar
brent.s
Member
 
Posts: 8
Joined: Thu Dec 03, 2015 2:08 pm
Location: Phoenix, AZ
Has thanked: 0 time
Been thanked: 0 time

Re: LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWIT

Mon Jun 06, 2016 1:37 pm

Has anyone tried to power a Cambium PtP820S radio off the Netonix yet?

I know it is a 48V unit, but not sure if there is any need for Pin swaps on one end for it to power correctly.

User avatar
cwachs
Experienced Member
 
Posts: 115
Joined: Fri Nov 06, 2015 9:04 pm
Location: Colorado
Has thanked: 2 times
Been thanked: 10 times

Re: LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWIT

Fri Jun 10, 2016 1:04 pm

What setting are people powering a Ignite MetroLinq with? Included power supply says 24v 1A. Does it use that full 1A? Are you using the 24VH on the Netonix?

User avatar
cwachs
Experienced Member
 
Posts: 115
Joined: Fri Nov 06, 2015 9:04 pm
Location: Colorado
Has thanked: 2 times
Been thanked: 10 times

Re: LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWIT

Sat Jun 11, 2016 1:01 pm

cwachs wrote:What setting are people powering a Ignite MetroLinq with? Included power supply says 24v 1A. Does it use that full 1A? Are you using the 24VH on the Netonix?


Finally found an answer:
MetroLinq
60 GHz - Port power should be set to 24VH (1.5A). Yup we tested it and confirmed no issue powering.

User avatar
sirhc
Employee
Employee
 
Posts: 7419
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWIT

Sat Jun 11, 2016 4:19 pm

You can power a Metrolink with 24V .75A but if you have a 24VH port available use it.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

givemesam
Member
 
Posts: 28
Joined: Sat May 21, 2016 1:50 am
Has thanked: 0 time
Been thanked: 1 time

Re: LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWIT

Fri Jun 17, 2016 1:17 am

i recommend making an edit to: viewtopic.php?f=6&t=1178

and say the metrolinq is supported fully on 24VH, and can also be powered on 24v. We have done both and it seems fine. (toughswitch did the 24v, and then got WISPsw and put it on the 24VH)

User avatar
gripper
Member
 
Posts: 27
Joined: Thu Aug 20, 2015 12:22 pm
Location: Central Vermont, USA
Has thanked: 1 time
Been thanked: 1 time

Re: LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWIT

Thu Jun 30, 2016 10:48 am

Has anybody tried:

Ceragon (IP-20c) ??

Radwin (5000 HPMP) ??

Wavion (2400Sect) ??

User avatar
gripper
Member
 
Posts: 27
Joined: Thu Aug 20, 2015 12:22 pm
Location: Central Vermont, USA
Has thanked: 1 time
Been thanked: 1 time

Re: LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWIT

Thu Jun 30, 2016 2:14 pm

Oops...just discovered an earlier post that confirms Ceragon IP-20C "do in fact work with 48VH PoE and consume about 45 watts when fully online."
Thx to sswireless....

George_EOL
Member
 
Posts: 3
Joined: Tue Mar 22, 2016 8:20 pm
Location: Tauranga, New Zealand
Has thanked: 0 time
Been thanked: 0 time

Re: LIST OF POEDEVICES THAT DO AN DO NOT WORK WITH WISP SWIT

Thu Jul 14, 2016 11:45 pm

gripper wrote:Has anybody tried:

Ceragon (IP-20c) ??

Radwin (5000 HPMP) ??

Wavion (2400Sect) ??



I have a Wavion/Alvarion N Sector running on the DC WISP Switch. 48VH but you need to run a crossover cable! 1+2>3+6 and vice versa. I haven't run up one of the b/g models yet but will have too soon!