However, the first switch has failed every single day since install. PoE remains to all output ports, but the device seems to go into a bootloop of some kind. Nothing is in the logs, no issues are seen when it is running fine etc etc. However, when it fails, we can see ports go link-layer down, coming back up for one second every few minutes.
Here are the relevant logs from the fine switch next to it; the inter-switch-link is on port 6:
- Code: Select all
Aug 1 12:01:13 kernel: link state changed to 'down' on port 6
Aug 1 12:01:26 kernel: link state changed to 'up' on port 6
Aug 1 12:01:27 kernel: link state changed to 'down' on port 6
Aug 1 12:02:21 kernel: link state changed to 'up' on port 6
Aug 1 12:02:22 kernel: link state changed to 'down' on port 6
Aug 1 12:24:41 kernel: link state changed to 'up' on port 6
Aug 1 12:24:42 kernel: link state changed to 'down' on port 6
Aug 1 12:33:33 kernel: link state changed to 'up' on port 6
Aug 1 12:33:35 kernel: link state changed to 'down' on port 6
Aug 1 12:57:41 kernel: link state changed to 'up' on port 6
Aug 1 12:57:43 kernel: link state changed to 'down' on port 6
Aug 1 12:58:57 kernel: link state changed to 'up' on port 6
Aug 1 12:58:59 kernel: link state changed to 'down' on port 6
Aug 1 13:24:22 kernel: link state changed to 'up' on port 6
Aug 1 13:24:23 kernel: link state changed to 'down' on port 6
This switch has been taking out an entire tower for a week and support threads have gone unanswered. I'd like to get in contact with Netonix directly regarding this issue if possible; I'd like to replace these with a WS-12-250-DC ASAP.
Thank you,
Frank