Power out of range? (3V)

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
sporkman
Member
 
Posts: 86
Joined: Mon Jul 27, 2015 7:03 pm
Location: New York, NY
Has thanked: 8 times
Been thanked: 11 times

Power out of range? (3V)

Fri Jul 15, 2016 2:18 pm

One of my WS-6-Mini switches has logged this a few times, is this anything to be concerned about?

Code: Select all
 
Jul 9 04:39:09 switch[1338]: 3V is out of range (3.1V)

Jul 12 22:30:50 switch[1338]: 3V is out of range (3.5V)

 


Running 1.4.2 final. Hardware/board rev. is "E".


Total power draw (switch and two radios) is under 20W.

(this is not the other switch I've been posting about recently)

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Power out of range? (3V)

Fri Jul 15, 2016 4:56 pm

No, it will not hurt anything.

The valid range is 3.135-3.465 so 3.1 and 3.5 are just outside that range.

It should not fluctuate unless there is something going on such as maybe grounding???
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

orders@xytel.net
Member
 
Posts: 4
Joined: Sun Jul 24, 2016 1:16 pm
Has thanked: 0 time
Been thanked: 0 time

Re: Power out of range? (3V)

Mon Jul 25, 2016 10:07 am

I'm getting the same thing on my WS-6-MINI, Interestingly enough, it only started after I updated to 1.4.2, previously on 1.3.8 (out of box firmware) I didn't have this issue... Nothing changed hardware wise.

User avatar
lligetfa
Associate
Associate
 
Posts: 1191
Joined: Sun Aug 03, 2014 12:12 pm
Location: Fort Frances Ont. Canada
Has thanked: 307 times
Been thanked: 381 times

Re: Power out of range? (3V)

Mon Jul 25, 2016 10:24 am

orders@xytel.net wrote:I'm getting the same thing on my WS-6-MINI...

On the same 3V line? The 48V line is prone to that error if there is a long line on PoE in and high current draw.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Power out of range? (3V)

Mon Jul 25, 2016 11:04 am

The next firmware version will correct this, try v1.4.3rc3
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: Power out of range? (3V)

Wed Aug 10, 2016 3:25 pm

sirhc wrote:The next firmware version will correct this, try v1.4.3rc3


Still showing up in 1.4.3rc4
Upgraded to it last night because the syslog alerts were driving me crazy...

Code: Select all
Jan 1 00:00:09 netonix: 1.4.3rc4 on WS-8-150-AC
Aug 10 15:09:33 switch[1334]: 3V is out of range (3.1V)


48V fluctuates about 4V
24V as much as 5 or 6
3V runs between 3.1 and 3.5

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Power out of range? (3V)

Wed Aug 10, 2016 3:27 pm

This could be an indication that:

1) The switch is not getting enough watts
2) There is a grounding issue - read this post viewtopic.php?f=17&t=1786&start=30#p13447
3) The switch is damaged or faulty
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: Power out of range? (3V)

Wed Aug 10, 2016 3:45 pm

Getting a pretty solid 123.2V at 59.9Hz in - just checked again.

Pretty sure grounding is OK, it's tests fine at the receptacle.
There is no tower involved - in a garage with a few UBNT cams/devices.

It's been in service just shy of a month, but don't recall these alerts happening the first couple weeks.

Have more coming.
Want me to plug another one in (along side) to see if it has the same alerts ?

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Power out of range? (3V)

Wed Aug 10, 2016 3:57 pm

jakematic wrote:Getting a pretty solid 123.2V at 59.9Hz in - just checked again.

OK that is not telling you how many DC watts the switch is getting that is telling you how many AC volts your power adapter is getting.
How are you powering this WS-6-MINI, what adapter?

jakematic wrote:Pretty sure grounding is OK, it's tests fine at the receptacle.
There is no tower involved - in a garage with a few UBNT cams/devices.

OK if there is no tower involved then there is no ground potential difference so probably not that/

jakematic wrote:It's been in service just shy of a month, but don't recall these alerts happening the first couple weeks.

Older firmware did not really tell you if there was problem like this, something put into recent firmware.
Put the latest rc version on just for good measures.

jakematic wrote:Want me to plug another one in (along side) to see if it has the same alerts ?

I would say swap the unit out with another unit and see yes.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: Power out of range? (3V)

Wed Aug 10, 2016 4:08 pm

sirhc wrote:OK that is not telling you how many DC watts the switch is getting that is telling you how many AC volts your power adapter is getting.
How are you powering this WS-6-MINI, what adapter?


Apologies - didn't notice this thread is for WS-6-MINI.
Switch in question is a WS-8-150-AC

sirhc wrote:Older firmware did not really tell you if there was problem like this, something put into recent firmware.
Put the latest rc version on just for good measures.


Upgraded to 1.4.2 before it went into service, and it was alerting with that version

sirhc wrote:I would say swap the unit out with another unit and see yes.


Will do.

Next
Return to Hardware and software issues

Who is online