Power out of range? (3V)

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Power out of range? (3V)

Fri Aug 19, 2016 9:36 am

hmm, the UAP-ACL uses 24 volts I think..are you setting its POE port to 24V?

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: Power out of range? (3V)

Fri Aug 19, 2016 9:39 am

Yes, and yes.


Image

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: Power out of range? (3V)

Fri Aug 19, 2016 9:41 am

I thought I posted this but here it is again.

Am sure you are wondering and I was curious to make sure the cable didn't get pinched or stretched


Image

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Power out of range? (3V)

Fri Aug 19, 2016 9:44 am

I was going to suggest to change the Ethernet cable as a test...

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: Power out of range? (3V)

Fri Aug 19, 2016 10:13 am

Powered off the port, changed the cable, and powered it back on.

Pre-made cable, same length.

Same results. Passes cable diagnostics, and the voltage is fluctuating again


Edit: current APC status


root@ubu:/Fedora# apcaccess
APC : 001,050,1196
DATE : 2016-08-19 10:13:30 -0400
HOSTNAME : ubu
VERSION : 3.14.10 (13 September 2011) debian
UPSNAME : ubu
CABLE : Custom Cable Smart
DRIVER : APC Smart UPS (any)
UPSMODE : Stand Alone
STARTTIME: 2016-08-17 21:47:42 -0400
MODEL : Smart-UPS 1500
STATUS : TRIM ONLINE
LINEV : 127.4 Volts
LOADPCT : 0.0 Percent Load Capacity
BCHARGE : 100.0 Percent
TIMELEFT : 335.0 Minutes
MBATTCHG : 50 Percent
MINTIMEL : 25 Minutes
MAXTIME : 0 Seconds
MAXLINEV : 127.4 Volts
MINLINEV : 127.4 Volts
OUTPUTV : 113.0 Volts
SENSE : High
DWAKE : 000 Seconds
DSHUTD : 090 Seconds
DLOWBATT : 02 Minutes
LOTRANS : 106.0 Volts
HITRANS : 127.0 Volts
RETPCT : 000.0 Percent
ITEMP : 27.0 C Internal
ALARMDEL : 5 seconds
BATTV : 27.2 Volts
LINEFREQ : 60.2 Hz
LASTXFER : UNKNOWN EVENT
NUMXFERS : 0
TONBATT : 0 seconds
CUMONBATT: 0 seconds
XOFFBATT : N/A
SELFTEST : NO
STESTI : 336
STATFLAG : 0x0700000A Status Flag
REG1 : 0x00 Register 1
REG2 : 0x00 Register 2
REG3 : 0x00 Register 3
MANDATE : 09/09/11
SERIALNO : AS1136210355
BATTDATE : 05/14/15
NOMOUTV : 120 Volts
NOMBATTV : 24.0 Volts
EXTBATTS : 0
FIRMWARE : 651.2.D
END APC : 2016-08-19 10:14:29 -0400

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Power out of range? (3V)

Fri Aug 19, 2016 10:20 am

ok, lets try below:

1) try a different port with same device
2) try a different device on same port

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: Power out of range? (3V)

Fri Aug 19, 2016 10:28 am

1) Steps:
- Powered off port 1
- moved cable to port 2
- powered on port 2 24V
- wait
- same result with voltages

2) Do you want powered or non-powered in port 1, or does the above test invalidate #2 ?

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Power out of range? (3V)

Fri Aug 19, 2016 10:32 am

#2), want to plug in a different POE device

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: Power out of range? (3V)

Fri Aug 19, 2016 10:41 am

Plugged a UVC-G3 into port 1 while port 2 was still online.
Same fluctuations.

Powered off port 2, stabilized for a moment, then started to fluctuate again, stabilized some, and is fluctuating again just as badly.

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Power out of range? (3V)

Fri Aug 19, 2016 10:46 am

how about try another set of ports, each pair of ports share an ethernet transformer on the board....try plugging into ports 3/4

PreviousNext