v1.4.5rcX Bug Reports and Comments

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.5rcX Bug Reports and Comments

Mon Sep 26, 2016 10:42 am

Fisher wrote:I'm still getting Out of Range log messages. A couple a day. This is an improvement over 1.4.4 where I could get a couple an hour.

Sep 22 12:09:29 switch[1322]: 24V is out of range (22.7V)
Sep 23 00:57:57 switch[1322]: 24V is out of range (22.7V)
Sep 23 03:36:48 switch[1322]: 24V is out of range (22.7V)
Sep 23 20:02:41 switch[1322]: 24V is out of range (22.7V)
Sep 24 08:39:19 switch[1322]: 24V is out of range (22.8V)
Sep 24 14:16:32 switch[1322]: 24V is out of range (22.7V)
Sep 25 19:11:11 switch[1322]: 24V is out of range (22.7V)
Sep 25 22:39:09 switch[1322]: 24V is out of range (22.8V)
Sep 26 07:51:31 switch[1322]: 24V is out of range (22.8V)


Then please RMA this unit for repair. viewtopic.php?f=6&t=1259
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

slowe
Member
 
Posts: 29
Joined: Sun May 01, 2016 9:47 pm
Has thanked: 1 time
Been thanked: 4 times

Re: v1.4.5rcX Bug Reports and Comments

Wed Sep 28, 2016 7:57 pm

I get the following error when I upgrade to the latest from on my 12 ports. Everything works fine post upgrade
Its line 4 and 5.

Image

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.5rcX Bug Reports and Comments

Wed Sep 28, 2016 7:59 pm

slowe wrote:I get the following error when I upgrade to the latest from on my 12 ports. Everything works fine post upgrade
Its line 4 and 5.


viewtopic.php?f=17&t=1806&p=13557&hilit=usr%2Fbin#p13557

sirhc wrote:The bug that generates that error is in v1.4.1 not v1.4.2.

Remember that the existing firmware version that is on the switch handles the upgrade procedure to the next version, it is fixed in v1.4.2 :D
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

nozlaf
Member
 
Posts: 5
Joined: Mon Aug 08, 2016 7:31 pm
Has thanked: 0 time
Been thanked: 0 time

Re: v1.4.5rcX Bug Reports and Comments

Wed Sep 28, 2016 11:20 pm

not sure if this has been raised in the past but i noticed that 1.4.2 has this issue too but passwords over a certain length are ignored

so I have a password of "laurahatesvideos!" but i can login with "laurahate" (not my actual passwords)

User avatar
dustinhinkel
Member
 
Posts: 9
Joined: Sun Oct 18, 2015 1:38 pm
Location: Omaha, Nebraska
Has thanked: 1 time
Been thanked: 0 time

Re: v1.4.5rcX Bug Reports and Comments

Mon Oct 10, 2016 10:34 am

Purchased 8 ws8-150-AC. All had 1.4.2 firmware upon installation. All were populated with 6 ports 24v poe and one uplink to another netonix switch. All had voltage fluctuations and stopped forwarding traffic/flapping ports at some point. Upgraded to 1.4.5rc2, this helped but did not fix the issue. Had to remove and put in tough switches. 12 port netonix in the same environment are working fine. Is there another fix planned for this going forward?

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.5rcX Bug Reports and Comments

Mon Oct 10, 2016 10:44 am

dustinhinkel wrote:Purchased 8 ws8-150-AC. All had 1.4.2 firmware upon installation. All were populated with 6 ports 24v poe and one uplink to another netonix switch. All had voltage fluctuations and stopped forwarding traffic/flapping ports at some point. Upgraded to 1.4.5rc2, this helped but did not fix the issue. Had to remove and put in tough switches. 12 port netonix in the same environment are working fine. Is there another fix planned for this going forward?


We did have some (less than 1%) WS-6-MINI and WS-8-150-XX units that went out with defective CAPs but the estimated # of units affected by this is less than 1% of that production batch so it seems very odd that you would have EIGHT of them but I suppose it is possible if you have terrible luck?

Anyway simply RMA them and we replace the defective CAPs and will send them back to you ASAP.

Please follow the RMA instructions located here: viewtopic.php?f=6&t=1259

All WS-6 and WS-8 switches with a Manufactured date of 9/7/2016 or newer have had the CAPs replaced, any unit older than that have had a 1% or less chance that their CAPs are defective.

But the symptoms of the unit having defective CAPs is that the voltages (3.3/24/48) on the device status Tab will fluctuate with anywhere from 4 or more Ethernet links active and on an even rarer instance this voltage 3.3V fluctuation can be just enough that the unit will reboot. The 24V and 48V are not really fluctuating but since those readings use the 3.3V reading as a baseline they also falsely report an exaggerated fluctuation.

The reason we missed this during testing is we do test each port one by one to achieve a 1G connection before we serialize the unit but not all ports are active at the same time and for this to show up 4 or more ports need to be active.

But there should be no way that the voltage fluctuation would cause traffic not to pass other than the unit is rebooting.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

v1.4.5rc4 released

Mon Oct 10, 2016 1:47 pm

v1.4.5rcX wrote:FIXED[b]/CHANGED[/b]
- Fixed voltage fluctuation that affected a small percentage of WS-6-MINI, WS-8-150-AC, WS-8-150-DC - rc1
- Updated SSH daemon to get more modern key exchange algorithm - rc1
- Watchdog no longer checks for link on port to be bounced - rc1
- ignore the SFP ports when checking Priority values - rc4
- changed throttle limits between switch core and CPU - rc4
- fixed web UI login only using the first 8 characters of the password - rc4
- removed Address from MODBUS configuration - rc4

ENHANCEMENTS
- Added option to bounce link instead of POE for watchdog rules - rc1
- Added support for 1000BASE-BX SFP modules (including Fiberstore SFP-GE-BX) - rc2

KNOWN ISSUES
- Some language templates need help - please contact us to help - rc1

Released 10/10/2016 - rc4
Released 9/21/2016 - rc2
Released 9/19/2016 - rc1
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
TheHox
Experienced Member
 
Posts: 107
Joined: Sat Sep 13, 2014 10:59 am
Location: WI
Has thanked: 11 times
Been thanked: 18 times

Re: v1.4.5rcX Bug Reports and Comments

Tue Oct 11, 2016 7:09 am

I just updated 5 switches to rc4, all went just fine, except one.

One of them was a Mini-6, and now after the update, I get a password error. I logged into it with the exact same login/password but now after the firmware update I can't login.
Any ideas or do I have to go reset it?

User avatar
Eric Stern
Employee
Employee
 
Posts: 532
Joined: Wed Apr 09, 2014 9:41 pm
Location: Toronto, Ontario
Has thanked: 0 time
Been thanked: 130 times

Re: v1.4.5rcX Bug Reports and Comments

Tue Oct 11, 2016 9:14 am

TheHox wrote:I just updated 5 switches to rc4, all went just fine, except one.

One of them was a Mini-6, and now after the update, I get a password error. I logged into it with the exact same login/password but now after the firmware update I can't login.
Any ideas or do I have to go reset it?


Can you SSH into it? If so, use these commands to reset the password from the CLI:

conf
credentials password <your password>
exit
exit

User avatar
TheHox
Experienced Member
 
Posts: 107
Joined: Sat Sep 13, 2014 10:59 am
Location: WI
Has thanked: 11 times
Been thanked: 18 times

Re: v1.4.5rcX Bug Reports and Comments

Tue Oct 11, 2016 8:18 pm

Eric Stern wrote:
TheHox wrote:I just updated 5 switches to rc4, all went just fine, except one.

One of them was a Mini-6, and now after the update, I get a password error. I logged into it with the exact same login/password but now after the firmware update I can't login.
Any ideas or do I have to go reset it?


Can you SSH into it? If so, use these commands to reset the password from the CLI:

conf
credentials password <your password>
exit
exit


That worked!

Thanks