WS-26-400-DC

User avatar
amishgenius
Associate
Associate
 
Posts: 102
Joined: Fri Apr 11, 2014 3:39 pm
Has thanked: 44 times
Been thanked: 45 times

Re: WS-26-400-DC

Wed Nov 30, 2016 4:29 pm

Yes please. 12 ports is just to small anymore. And no, 9-36vdc is NOT enough. 9-70vdc is good.

User avatar
amishgenius
Associate
Associate
 
Posts: 102
Joined: Fri Apr 11, 2014 3:39 pm
Has thanked: 44 times
Been thanked: 45 times

Re: WS-26-400-DC

Thu Dec 01, 2016 9:01 am

So wait, only two 24vdc High Power?

There are a lot of AF5x being installed, and those are 24v. I would think two might not be enough.

User avatar
sirhc
Employee
Employee
 
Posts: 7422
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: WS-26-400-DC

Thu Dec 01, 2016 9:09 am

amishgenius wrote:So wait, only two 24vdc High Power?

There are a lot of AF5x being installed, and those are 24v. I would think two might not be enough.

Why would you power an AFX radio with 24VH instead of 48VH?

Please read these posts Sam:
viewtopic.php?f=6&t=2013&p=16324&hilit=AFX#p16324
viewtopic.php?f=12&t=1960&p=16147&hilit=AFX#p16147

The AF5X can be powered by:
24V up to 160 feet +/- of cable < Least prefered method
48V up to 200 feet +/- of cable < Better method
24VH up to 326 feet +/- of cable < Even better method
48VH up to 326 feet +/- of cable < Preferred method

The AFX radios can actually use all 4 POE options we have as seen above.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
amishgenius
Associate
Associate
 
Posts: 102
Joined: Fri Apr 11, 2014 3:39 pm
Has thanked: 44 times
Been thanked: 45 times

Re: WS-26-400-DC

Thu Dec 01, 2016 9:57 am

Apparently I've been living under a rock :(

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: WS-26-400-DC

Thu Dec 01, 2016 11:12 am

UMMM. you ain't the only one.....i moved under my rock years ago apparently...

User avatar
Omniflux
Experienced Member
 
Posts: 113
Joined: Tue Feb 24, 2015 3:04 pm
Has thanked: 5 times
Been thanked: 32 times

Re: WS-26-400-DC

Sat Dec 03, 2016 3:52 pm

I just ran into a case today where I will be deploying two WS-12-250-DC because I need more ports.

sirhc wrote:(2) SFP port
We are not using SFP+ anywhere yet, but I am surprised it is not yet standard. With this many copper ports, I think it probably makes sense to make the jump now; we are bonding ports already to increase capacity to 2Gbps in some places.

Dave wrote:or would a voltage range of say 9-36 volts be good enough, assuming most WISP guys are using 24 volt battery systems......

Our solar sites are 48V which can range as high as 72V if equalization occurs during the right hours in winter.

At our grid sites, our battery backup systems are usually 24V and rather than convert back to AC, we run directly off the batteries. Sometimes it makes sense to place the Netonix closer to the radios than to the batteries though, and we bump up to 48V for the longer cable run.

sirhc wrote:The WS-26-400-IDC (note the "I" in the model number which stands for Isolated) will be 13" x 12" x 1.5" and will be for NEGATIVE 48V DC Telco sites.

This will simplify things at some of our sites where we have both -48V and +24/48V equipment by allowing us to use one less device.

sirhc wrote:The WS-26-500-DC at 13" x 10" x 1.5", a larger spin on our existing WS-12-250-DC, a SMART DC switch.

This sounds very nice, but I am afraid the 500 is a typo and the thread topic is correct...

sirhc wrote:They would all support Wall Mount, Rack Mount, and Desktop applications.

DIN mount still possible?

sirhc wrote:Weigh in now or forever hold your complaints we do not offer one.

Hereby reserving my right to complain.

User avatar
Dawizman
Experienced Member
 
Posts: 141
Joined: Fri Jul 03, 2015 4:11 pm
Location: Cold Lake, AB - CANADA
Has thanked: 15 times
Been thanked: 22 times

Re: WS-26-400-DC

Wed Dec 14, 2016 12:04 am

I have a few sites where I could use this switch right now. We have standardized on a 48V DC system at our sites, so a switch that handles up to 70 V would be perfect, as our solar sites can ideally hit up to 64V in our climate in the winter.

I also have a use for the 48V-IDC switches. It would allow us to get rid of the inverters that we currently use at our fiber provider sites. Off the top of my head, I could order 6 of each switch as soon as they are released, and at the rate we are expanding, a couple more every month.

User avatar
sirhc
Employee
Employee
 
Posts: 7422
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: WS-26-400-DC

Wed Dec 14, 2016 12:14 am

Dawizman wrote:I have a few sites where I could use this switch right now. We have standardized on a 48V DC system at our sites, so a switch that handles up to 70 V would be perfect, as our solar sites can ideally hit up to 64V in our climate in the winter.

I also have a use for the 48V-IDC switches. It would allow us to get rid of the inverters that we currently use at our fiber provider sites. Off the top of my head, I could order 6 of each switch as soon as they are released, and at the rate we are expanding, a couple more every month.


You do realize our Rev F WS-8-150-DC and WS-12-250-DC can handle 72V input
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
Dawizman
Experienced Member
 
Posts: 141
Joined: Fri Jul 03, 2015 4:11 pm
Location: Cold Lake, AB - CANADA
Has thanked: 15 times
Been thanked: 22 times

Re: WS-26-400-DC

Wed Dec 14, 2016 12:20 am

sirhc wrote:
You do realize our Rev F WS-8-150-DC and WS-12-250-DC can handle 72V input


I do, yes, and I thank you for that! We are able to better charge our batteries during the winter months now. I was just specifying that the 72V maximum is a huge plus to us. Somebody had posted that 36V might be plenty.

User avatar
highlands
Member
 
Posts: 52
Joined: Fri Oct 09, 2015 1:01 pm
Has thanked: 4 times
Been thanked: 2 times

Re: WS-26-400-DC

Tue Dec 27, 2016 11:26 am

Up to 72VDC is great and in my opinion where the top end should be based of typical voltage ranges for 48VDC gear.
24 Copper ports are good too.
2 SFP port I believe is perfect.
The smaller form factor is good and I wish all units came with rack ears.
Any chance that an option could be incorporated to switch off all LEDs? with 26 ports and 2 per port its starting to add up.
As a switch ONLY I would say you have built a great product!

It is a opinion again however I see in time you adding 8 analog inputs, 8 digital inputs, 8 digital outputs and 8 10amp relays. Then just like DLI does on their Open Source WiFi PLC also have a bus that can take an add on Full Arduino MEGA compatibility! Your device already has at least half of the basic functions needed.

If you were to 'marry' those two products together........WOW is all I can say! Remote telemetry from a un-manned site is king and very important. The inputs can monitor voltage, current, temperature, water levels and anything you can think of. The Digital inputs can monitor doors, movement sensors, other simple alarms that only offer a relay closure, and more. Digital outputs can turn on or off power to any number of devices.

John

PreviousNext
Return to General Discussion

Who is online