Cold temps WS-8-250-DC Power Supply Board Temp 4 million deg

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
mtngoat
Member
 
Posts: 24
Joined: Mon Feb 16, 2015 3:37 pm
Has thanked: 2 times
Been thanked: 5 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Sat Dec 17, 2016 7:23 pm

I left it unplugged for 10 seconds maybe, it was a high traffic site. I can try longer, I am heading out to one site now.

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Sat Dec 17, 2016 7:34 pm

I left it unplugged for 10 seconds maybe, it was a high traffic site. I can try longer, I am heading out to one site now.


ya, that's not long enough for sure, the problem is when in hibernate mode, only a really low power micro is running, so it will take a while for the local
caps to discharge so the micro actually shuts down.

my guess is you will need to leave it un-powered for at least a couple of minutes.

User avatar
mtngoat
Member
 
Posts: 24
Joined: Mon Feb 16, 2015 3:37 pm
Has thanked: 2 times
Been thanked: 5 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Sat Dec 17, 2016 7:43 pm

I reverted to firmware 1.4.2 on one. When I check on it over an hour later, the temperature was back to normal and the fan was off. I upgraded the firmware back to 1.4.6 and the temperature is normal for the Power Supply Board Temp. Probably just an anomaly by reverting back. The other one is still acting up and I am heading there shortly. I will try unplugging for multiple minutes. If this doesn't work, I have a WS-8-150-DC to put in.

User avatar
mtngoat
Member
 
Posts: 24
Joined: Mon Feb 16, 2015 3:37 pm
Has thanked: 2 times
Been thanked: 5 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Sun Dec 18, 2016 1:10 am

When I went to check on the 2nd unit, it was acting normally as well. No spiked temperature and the fan was off. So time seems to help this odd issue. The batteries should be sufficient to make it through the night so hopefully no repeat.

User avatar
LRL
Experienced Member
 
Posts: 238
Joined: Sun Nov 23, 2014 4:00 am
Location: Rock Springs, WY
Has thanked: 18 times
Been thanked: 49 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Mon Dec 19, 2016 12:24 am

I'm seeing the same thing on one site, except I see high board and cpu Temps. The CPU temp bounced from 0 to 242 and back to what I think is the actual. It's currently -7f at that location.

Both stayed pegged at 242 and I rebooted the switch and the cpu started flapping back and forth.

12-18-2016 11-10-07 PM.png
-LRL

"My reading of history convinces me that most bad government results from too much government." - Thomas Jefferson

User avatar
mtngoat
Member
 
Posts: 24
Joined: Mon Feb 16, 2015 3:37 pm
Has thanked: 2 times
Been thanked: 5 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Mon Dec 19, 2016 1:13 pm

Since Saturday afternoon, the units have been working as expected. No high temperatures sensed or cooling fan running that I have witnessed through the GUI. They have not entered hibernation since the solar has been keeping up. The extreme cold temperatures are also subsiding. I find it interesting that both units eventually got over their false 'fevers' and resumed normal operation without the power being unplugged for multiple minutes.

One site seems to be draining the battery quicker, but the battery capacity may be lacking due to the cold. So even running a generator and battery charger and the solar charging hasn't kept the charge above 12 V last night.

User avatar
LRL
Experienced Member
 
Posts: 238
Joined: Sun Nov 23, 2014 4:00 am
Location: Rock Springs, WY
Has thanked: 18 times
Been thanked: 49 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Tue Dec 20, 2016 11:36 pm

On another note about cold temps. I tend to see a lot of fan failure notices when things get cold. It appears the fan being cold takes longer than the software allows before generating the alert. You guys might think about tweaking the timers a little.
-LRL

"My reading of history convinces me that most bad government results from too much government." - Thomas Jefferson

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Tue Dec 20, 2016 11:44 pm

ya, we need to stick Eric & a switch out in the arctic snow for awhile to figure this out... :working:

User avatar
lligetfa
Associate
Associate
 
Posts: 1191
Joined: Sun Aug 03, 2014 12:12 pm
Location: Fort Frances Ont. Canada
Has thanked: 307 times
Been thanked: 381 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Wed Dec 21, 2016 12:20 am

Dave wrote:ya, we need to stick Eric & a switch out in the arctic snow for awhile to figure this out... :working:

Dave and Eric testing.jpg

User avatar
mtngoat
Member
 
Posts: 24
Joined: Mon Feb 16, 2015 3:37 pm
Has thanked: 2 times
Been thanked: 5 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Tue Jan 03, 2017 12:47 pm

Cold temperatures are back and so are the crazy board temperatures. I replaced one WS-8-250-DC that had crazy perceived temperatures with a WS-8-150-DC and here is the screen shot.