Cold temps WS-8-250-DC Power Supply Board Temp 4 million deg

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Tue Jan 03, 2017 1:01 pm

we do have new test code for this issue...let me get Eric to send to you.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Tue Jan 03, 2017 1:52 pm

I went ahead and released v1.4.7rc3 which should fix temp issue.

viewtopic.php?f=17&t=240&p=848#p848
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
mtngoat
Member
 
Posts: 24
Joined: Mon Feb 16, 2015 3:37 pm
Has thanked: 2 times
Been thanked: 5 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Tue Jan 03, 2017 2:00 pm

The temperature did get fixed with the update to v1.4.7rc3. It has been up for 35 minutes since upgrading and I still have high cooling fan speed (perhaps heating fan at this temp) .

jan2.JPG

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Tue Jan 03, 2017 2:57 pm

thanks for the quick post...yup, seems we still have minor issue to fix...we will have rc fix for fans & Chris will post when ready.

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Tue Jan 03, 2017 5:25 pm

mtngoat

thanks for the quick post...yup, seems we still have minor issue to fix...we will have rc fix for fans & Chris will post when ready.


please download wispswitch-1.4.7rc4.bin again & retry....think we fixed FAN issue now.

thanks

Dave

User avatar
mtngoat
Member
 
Posts: 24
Joined: Mon Feb 16, 2015 3:37 pm
Has thanked: 2 times
Been thanked: 5 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Tue Jan 03, 2017 6:09 pm

I updated the firmware to 1.4.7rc4. The fan had already turned off before I upgraded. Tonight is another cold night to test it out.

User avatar
mtngoat
Member
 
Posts: 24
Joined: Mon Feb 16, 2015 3:37 pm
Has thanked: 2 times
Been thanked: 5 times

Re: Cold temps WS-8-250-DC Power Supply Board Temp 4 million

Fri Jan 06, 2017 1:02 pm

I haven't had an issue with the temperature or the fan since I upgraded to the 1.4.7rc4 firmware. :hurray:

Previous
Return to Hardware and software issues

Who is online

Users browsing this forum: No registered users and 61 guests