Seen this on two units so far, looks like the power cord in these instance that comes with the kit isn't making proper contact with the unit. Any slight movement to the cable and the unit will lose power.
After the cable is replaced all is fine.
Two unit info (WS-12-250-AC):
MAC: EC:13:B2:61:BC:82
MAC: EC:13:B2:61:BC:66 Mfr date: 2016/09/14
Bad powercords?
- Julian
Re: Bad powercords?
we had a batch that were tough to insert fully, and you'd see that.. Nothing firm pressure couldn't fix though.
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Bad powercords?
Yes, the first insert requires a little extra pressure but then after that they go in just fine.
We went with ones that push in hard the first time but stay in as we also had them the other way where they pushed in easy the first time but could fall out easier.
We went with ones that push in hard the first time but stay in as we also had them the other way where they pushed in easy the first time but could fall out easier.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
lligetfa - Associate
- Posts: 1191
- Joined: Sun Aug 03, 2014 12:12 pm
- Location: Fort Frances Ont. Canada
- Has thanked: 307 times
- Been thanked: 381 times
Re: Bad powercords?
ISTR mentioning wanting a place to zip tie the cord in my very first review years ago. Don't mean for it to be "I told you so" but zip tying the cord is a best practice I like to do.
-
mayheart - Experienced Member
- Posts: 166
- Joined: Thu Jan 15, 2015 1:42 pm
- Location: Canada
- Has thanked: 43 times
- Been thanked: 40 times
Re: Bad powercords?
Yeah the two cables that we received are very loose, even when pushed in hard.
They both fell out on the bench while configuring it.
They both fell out on the bench while configuring it.
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Bad powercords?
mayheart wrote:Yeah the two cables that we received are very loose, even when pushed in hard.
They both fell out on the bench while configuring it.
When I say Push in hard the first time I mean HARD. I sent a hole shipment back once to factory and they schooled me on what I was doing wrong.
Should look like below when fully inserted:
CLICK IMAGE TO VIEW FULL SIZE
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
6 posts
Page 1 of 1
Who is online
Users browsing this forum: Google [Bot] and 79 guests