I'd like to know how much of what we talked about here has been implemented in the 1.4.7rc4.
I see from the release notes that the disabling of 48V ports is no longer stored in the configuration. This is great, but are the ports re-powered when the power is over a given level again?
Thanks.
How to prevent the disabling of 48V ports?
-
Eric Stern - Employee
- Posts: 532
- Joined: Wed Apr 09, 2014 9:41 pm
- Location: Toronto, Ontario
- Has thanked: 0 time
- Been thanked: 130 times
-
giannici - Member
- Posts: 46
- Joined: Thu Nov 12, 2015 9:48 am
- Location: Palermo, Italy
- Has thanked: 0 time
- Been thanked: 2 times
Re: How to prevent the disabling of 48V ports?
Eric Stern wrote:Yes.
OK.
Can we know what are the two threshold levels (off and on)?
Are the other things discussed in this topic implemented too?
Thanks.
-
Eric Stern - Employee
- Posts: 532
- Joined: Wed Apr 09, 2014 9:41 pm
- Location: Toronto, Ontario
- Has thanked: 0 time
- Been thanked: 130 times
Re: How to prevent the disabling of 48V ports?
giannici wrote:Can we know what are the two threshold levels (off and on)?
It will shut off 48V PoE when the input voltage is < 43V for 5 seconds.
It will turn power back on when the input voltage is > 47V.
giannici wrote:Are the other things discussed in this topic implemented too?
Which other things?
Who is online