v1.4.7rcX Bug Reports and Comments

DOWNLOAD THE LATEST FIRMWARE HERE
IntL-Daniel
Experienced Member
 
Posts: 170
Joined: Mon Nov 02, 2015 5:07 pm
Location: Czech Republic
Has thanked: 7 times
Been thanked: 9 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Feb 28, 2017 2:53 pm

sirhc wrote:If the radios rebooted there should be record in the switch log of the port going down and back up (twice), is there?

Did you log into the radios and confirm they rebooted? (up time)?

Do you have a watchdog set up in the radios themselves?

I have AF radios all over the place and I see the Flow Control turned OFF all the time and have never seen this behavior on any of my switches so my opinion is there is something else a foot here.


1/ Yes, twice.
2/ Yes, all three exactly the same uptime... started "exactly" at moment of detected pause frame storm.
3/ No

So I only think of some bug when the pause frame storm is detected and watchdog on some independent port(s) set - it powercycle the port(s)?

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Feb 28, 2017 3:47 pm

I am telling you there is no bug, something else is afoot here, I am 99.9% sure of this.

I have a lot of these switches in my WISP and I also have 20 AF links and I get Flow Control turned off every time it rains and I never see this.

Now if I saw it or other people were reporting this I would say yea it must be a bug but with 30,000+ switches out there this is the only report of such an issue.

Did you login to the radio and make sure the radio has no ping watchdog setup?

Now we are supposed to get a LOT of rain in the next 2 days so I will watch all my switches and look for this behavior when FC gets disabled by Storm Protection but I am not expecting to see anything.

I will ask Eric to check his code to see if even possible.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

IntL-Daniel
Experienced Member
 
Posts: 170
Joined: Mon Nov 02, 2015 5:07 pm
Location: Czech Republic
Has thanked: 7 times
Been thanked: 9 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Feb 28, 2017 3:51 pm

sirhc wrote:Did you login to the radio and make sure the radio has no ping watchdog setup?

Now we are supposed to get a LOT of rain in the next 2 days so I will watch all my switches and look for this behavior when FC gets disabled by Storm Protection but I am not expecting to see anything.

I will ask Eric to check his code to see if even possible.

Yes loged in and no watchdog set in the radio. Maybe it has something to do with 48V vs watchdog vs pauseframe storm ? I have no idea...I have just described what I saw...thanks for your further investigating.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

v1.4.7rc14 Released

Tue Mar 07, 2017 3:11 pm

v1.4.7rcX wrote:NOTE: MSTP is still being tested so use MSTP at your own risk.

FIXED/CHANGED
- Fixed temp sensors showing crazy values in very cold environments - RC3
- Fixed getting "unexpected link change" messages due to port bounce, watchdogs, etc - RC3
- Fixed port bounce being 1 hour off after daylight savings time changes - RC3
- Fixed VLAN tab layout getting messed up when you delete a VLAN - RC3
- Fixed mac table refresh button causing entire page to reload - RC3
- Fixed problem with QinQ when using untagged VLANs - RC3
- Fixed fan control handling negative temperatures - RC4
- Fixed input voltage graph labels - RC4
- Fixed Apply/Save becoming active when looking at MSTP configuration even though nothing changed - RC6
- Fixed port number in log messages - RC6
- Fixed issue when importing config from a RevE board to a RevF with different POE port options. Affected WS-6 and WS-12 - RC6
- Fixed the support for WS-8-150-AC - RC7
- Fixed console login
- Fixed/Force powerdown/powerup limits on WS-8-150-DC to help prevent switch lock up when draining battery to 9V - RC8
- Fixed DC2DC-500 detection for WS-26-500-DC - RC8
- Fixed voltage range on dumb DC models - RC8
- Fixed QinQ - RC9
- Fixed VLAN trunking - RC9
- Fixed Access Controls not honouring the Enable setting - RC11
- Fixed switch rebooting if multiple ports lose link too quickly - RC14
- Fixed multiple ports not turning off at the same time when they have the same shutdown voltage - RC14
- Fixed unexpected link change speed message - RC14
- Fixed port selection Tabs - RC14
- Allow QinQ and Double Tagging to be used with Trunk ports - RC9
- Changed UI layout on QOS tab - RC3
- Changed dumb DC models to temporarily disable POE when input voltage falls too low instead of disabling POE in the configuration - RC3
- Changed valid DC input voltage range to 9-72V in GUI for newer board revs - RC3
- Changed valid upper range for dc output voltage from 51V to 53V - RC3
- Changed input voltage graph to auto-scale - RC3
- Changed fan control to also use CPU and PHY temp - RC6
- Changed valid temp range on Status page meters - RC6
- Changed the input voltage threshold where it forgets the configured Wake up voltage and defaults to 10V Wake up on WS-12-250-DC - RC10

ENHANCEMENTS
- Added MSTP - RC3
- Automatically disable flow control on ports using QOS bandwidth limits to prevent packet locks - RC3
- Added restart timer to DC power supply to help in very cold environments with cold starts - RC3
- Added log message when time is set by NTP after boot is finished - RC3
- Added logging when STP selects new root port - RC3
- Added POE startup delay option on Power tab - RC3
- Added root path cost on STP tab - RC3
- Added portDuplex SNMP stat from CISCO-STACK-MIB - RC3
- Added ifAdminStatus to SNMP stats - RC3
- Added support for new WS-26 models - RC6
- Added Double Tagged to VLAN configuration - RC6
- Added IP Protocol to QoS rules - RC11
- Added CIDR notation in QoS Source IP rules - RC11
- Added option to log web and ssh logins - RC11
- Added LLDP-MIB and CISCO-CDP-MIB to SNMP - RC 14
- Added option to change MAC aging time - RC14

KNOWN ISSUES
- Some language templates need help - please contact us to help

RC3 Released 1/3/2017
RC4 Released 1/3/2017
RC6 Released 1/26/2017
RC7 Released 1/27/2017
RC8 Released 2/7/2017
RC9 Released 2/16/2017
RC10 Released 2/20/2017
RC11 Released 2/22/2017
RC14 Released 3/7/2017
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

IntL-Daniel
Experienced Member
 
Posts: 170
Joined: Mon Nov 02, 2015 5:07 pm
Location: Czech Republic
Has thanked: 7 times
Been thanked: 9 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Mar 07, 2017 3:30 pm

Are there some changes in RC14 related to my last post Sirhc? (red colored maybe?)

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Mar 07, 2017 3:32 pm

IntL-Daniel wrote:Are there some changes in RC14 related to my last post Sirhc? (red colored maybe?)


No, what ever is going on at your location is not a switch/firmware issue is my "guess" as you are the only person having this issue?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

IntL-Daniel
Experienced Member
 
Posts: 170
Joined: Mon Nov 02, 2015 5:07 pm
Location: Czech Republic
Has thanked: 7 times
Been thanked: 9 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Mar 07, 2017 3:45 pm

So maybe one more detail..all three rebooted devices use the same 802.3af POE injector http://www.planet.com.tw/en/product/pro ... p?id=30135 ...so maybe if there could be some incompatibility problem?

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Mar 07, 2017 5:34 pm

IntL-Daniel wrote:So maybe one more detail..all three rebooted devices use the same 802.3af POE injector http://www.planet.com.tw/en/product/pro ... p?id=30135 ...so maybe if there could be some incompatibility problem?


Say what?

Make a diagram of exactly what you were doing, show our switch, this POE injector and devices powered.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
tma
Experienced Member
 
Posts: 122
Joined: Tue Mar 03, 2015 4:07 pm
Location: Oberursel, Germany
Has thanked: 15 times
Been thanked: 14 times

Re: v1.4.7rcX Bug Reports and Comments

Wed Mar 08, 2017 1:49 am

These devices are splitters, not injectors :-)
--
Thomas Giger

IntL-Daniel
Experienced Member
 
Posts: 170
Joined: Mon Nov 02, 2015 5:07 pm
Location: Czech Republic
Has thanked: 7 times
Been thanked: 9 times

Re: v1.4.7rcX Bug Reports and Comments

Wed Mar 08, 2017 1:57 am

Yes the name "fault"..the rest is relevant.

PreviousNext
Return to Hardware and software issues

Who is online

Users browsing this forum: No registered users and 16 guests