v1.4.7rcX Bug Reports and Comments

DOWNLOAD THE LATEST FIRMWARE HERE
Julian
 

Re: v1.4.7rcX Bug Reports and Comments

Thu Mar 09, 2017 5:01 pm

if you do not change the FC dropdown, it isn't applied to every port. Does seem a little weird, though, will discuss with Eric

User avatar
lligetfa
Associate
Associate
 
Posts: 1191
Joined: Sun Aug 03, 2014 12:12 pm
Location: Fort Frances Ont. Canada
Has thanked: 307 times
Been thanked: 381 times

Re: v1.4.7rcX Bug Reports and Comments

Thu Mar 09, 2017 5:02 pm

Chris, he's talking about flow control, not PoE. He only used the PoE dropdown to show what a blank option is.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.7rcX Bug Reports and Comments

Thu Mar 09, 2017 5:56 pm

What firmware are you running? I am running v1.4.7rc14
What browser, I am running Chrome.

Multi.png
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

IntL-Daniel
Experienced Member
 
Posts: 170
Joined: Mon Nov 02, 2015 5:07 pm
Location: Czech Republic
Has thanked: 7 times
Been thanked: 9 times

Re: v1.4.7rcX Bug Reports and Comments

Thu Mar 09, 2017 6:04 pm

Firefox 52, I see the same as you and it is not the point of the issue. Read my post again please.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.7rcX Bug Reports and Comments

Thu Mar 09, 2017 6:06 pm

IntL-Daniel wrote:Firefox 52, I see the same as you and it is not the point of the issue. Read my post again please.


Ah - DUH, you are saying there should be a BLANK option in Flow Control (or any drop down when using multi port select) so it does not mess with individual port settings in place????
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

IntL-Daniel
Experienced Member
 
Posts: 170
Joined: Mon Nov 02, 2015 5:07 pm
Location: Czech Republic
Has thanked: 7 times
Been thanked: 9 times

Re: v1.4.7rcX Bug Reports and Comments

Thu Mar 09, 2017 6:25 pm

I say that FC column should be the same as the rest of columns to be sure that if I leave fc column untouched then it does not set "None" to all ports.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.7rcX Bug Reports and Comments

Thu Mar 09, 2017 6:36 pm

I have alerted the "Eric" to your plea and he should address this in the next release
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
juanvi
Member
 
Posts: 14
Joined: Thu Apr 07, 2016 10:07 am
Location: Spain
Has thanked: 7 times
Been thanked: 2 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Apr 04, 2017 11:53 am

One QoS question:

If a frame arrives to switch with vlan 54 and 802.1p PCP value 7 in a port with this vlan allowed and must go out for another port with this vlan allowed too,

Is PCP changed in any way during this travel?

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

v1.4.7rc16 Released

Tue Apr 04, 2017 4:05 pm

v1.4.7rcX wrote:NOTE: MSTP is still being tested so use MSTP at your own risk.

FIXED/CHANGED
- Fixed temp sensors showing crazy values in very cold environments - RC3
- Fixed getting "unexpected link change" messages due to port bounce, watchdogs, etc - RC3
- Fixed port bounce being 1 hour off after daylight savings time changes - RC3
- Fixed VLAN tab layout getting messed up when you delete a VLAN - RC3
- Fixed mac table refresh button causing entire page to reload - RC3
- Fixed problem with QinQ when using untagged VLANs - RC3
- Fixed fan control handling negative temperatures - RC4
- Fixed input voltage graph labels - RC4
- Fixed Apply/Save becoming active when looking at MSTP configuration even though nothing changed - RC6
- Fixed port number in log messages - RC6
- Fixed issue when importing config from a RevE board to a RevF with different POE port options. Affected WS-6 and WS-12 - RC6
- Fixed the support for WS-8-150-AC - RC7
- Fixed console login
- Fixed/Force powerdown/powerup limits on WS-8-150-DC to help prevent switch lock up when draining battery to 9V - RC8
- Fixed DC2DC-500 detection for WS-26-500-DC - RC8
- Fixed voltage range on dumb DC models - RC8
- Fixed QinQ - RC9
- Fixed VLAN trunking - RC9
- Fixed Access Controls not honouring the Enable setting - RC11
- Fixed switch rebooting if multiple ports lose link too quickly - RC14
- Fixed multiple ports not turning off at the same time when they have the same shutdown voltage - RC14
- Fixed unexpected link change speed message - RC14
- Fixed port selection Tabs - RC14
- Fixed slight glitch in Input Current graph - RC16
- Allow QinQ and Double Tagging to be used with Trunk ports - RC9
- Changed UI layout on QOS tab - RC3
- Changed dumb DC models to temporarily disable POE when input voltage falls too low instead of disabling POE in the configuration - RC3
- Changed valid DC input voltage range to 9-72V in GUI for newer board revs - RC3
- Changed valid upper range for dc output voltage from 51V to 53V - RC3
- Changed input voltage graph to auto-scale - RC3
- Changed fan control to also use CPU and PHY temp - RC6
- Changed valid temp range on Status page meters - RC6
- Changed input voltage threshold where it forgets the configured Wake up voltage and defaults to 10V Wake up on WS-12-250-DC - RC10

ENHANCEMENTS
- Added MSTP - RC3
- Automatically disable flow control on ports using QOS bandwidth limits to prevent packet locks - RC3
- Added restart timer to DC power supply to help in very cold environments with cold starts - RC3
- Added log message when time is set by NTP after boot is finished - RC3
- Added logging when STP selects new root port - RC3
- Added POE startup delay option on Power tab - RC3
- Added root path cost on STP tab - RC3
- Added portDuplex SNMP stat from CISCO-STACK-MIB - RC3
- Added ifAdminStatus to SNMP stats - RC3
- Added support for new WS-26 models - RC6
- Added Double Tagged to VLAN configuration - RC6
- Added IP Protocol to QoS rules - RC11
- Added CIDR notation in QoS Source IP rules - RC11
- Added option to log web and ssh logins - RC11
- Added LLDP-MIB and CISCO-CDP-MIB to SNMP - RC 14
- Added option to change MAC aging time - RC14
- Added "Disable Power" action to watchdog - RC16

KNOWN ISSUES
- Some language templates need help - please contact us to help

RC3 Released 1/3/2017
RC4 Released 1/3/2017
RC6 Released 1/26/2017
RC7 Released 1/27/2017
RC8 Released 2/7/2017
RC9 Released 2/16/2017
RC10 Released 2/20/2017
RC11 Released 2/22/2017
RC14 Released 3/7/2017
RC16 Released 4/4/2017
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

IntL-Daniel
Experienced Member
 
Posts: 170
Joined: Mon Nov 02, 2015 5:07 pm
Location: Czech Republic
Has thanked: 7 times
Been thanked: 9 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Apr 04, 2017 4:24 pm

I have noticed one borring feature or bug ? - when I change the name of some port which is used in watchdog table, the name is not changed there as well. I have to manually edit watchdog rule port number to other and back and click save (last seen in RC14).