WS-8-150DC BLACKOUT

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
quadra
Experienced Member
 
Posts: 143
Joined: Sat Oct 31, 2015 8:25 am
Location: France
Has thanked: 3 times
Been thanked: 2 times

Re: WS-8-150DC BLACKOUT

Fri Apr 07, 2017 4:54 pm

je vais faire la mise a jour demain je vous tiendrais au courant

merci

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-8-150DC BLACKOUT

Fri Apr 07, 2017 5:02 pm

quadra wrote:je vais faire la mise a jour demain je vous tiendrais au courant

merci


If it rebooted when you plugged another device into it the firmware probably will not fix it and you will need to RMA it as that is that the defective 3.3V CAP issue causes.

There are 2 levels to the defective CAP issues:
Level 1) It messes up voltage readings which the firmware can fix

Level 2) It causes reboots when you use more ports and the firmware will not fix that issue the only fix is for us to replace the defective CAP.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
quadra
Experienced Member
 
Posts: 143
Joined: Sat Oct 31, 2015 8:25 am
Location: France
Has thanked: 3 times
Been thanked: 2 times

Re: WS-8-150DC BLACKOUT

Fri Apr 07, 2017 5:25 pm

je ne peux pas renvoyer le ws 8 150 le boitier a été ouvert pour notre installation et n'est plus garantie .... :willy:

il est installé dans notre église .
Attachments
eglise.PNG

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-8-150DC BLACKOUT

Fri Apr 07, 2017 6:03 pm

If it is the defective CAP issue it is warrantied no matter what for so long as the switch exists.

Or if you want we can tell you how to fix it "if" you're good at soldering.

But not sure why you took the board out of its chassis????
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
quadra
Experienced Member
 
Posts: 143
Joined: Sat Oct 31, 2015 8:25 am
Location: France
Has thanked: 3 times
Been thanked: 2 times

Re: WS-8-150DC BLACKOUT

Sat Apr 08, 2017 2:52 am

Bonjour

oui je peux souder éventuellement donner moi la procédure? :hurray:

nous avons supprimer le chassie car il était trop gros par rapport a la batterie quand t'on ferme le coffret , mais cela nous va très bien car nous avons construit tout les switch comme cela et c'est impeccable !

User avatar
quadra
Experienced Member
 
Posts: 143
Joined: Sat Oct 31, 2015 8:25 am
Location: France
Has thanked: 3 times
Been thanked: 2 times

Re: WS-8-150DC BLACKOUT

Sat Apr 08, 2017 5:48 am

Bonjour

voilà je suis donc retourné sur mon chantier, j'ai relancé le WS 8 DC manuellement en débranchant la batterie et il est repartie sans problème mais jusqu’à quand ?

J’ai fait la mise à jour RC18 aussi … et ci-joint l’adresse MAC du switch

J’ai coupé la caméra 48VH au cas où ….

Par contre j’ai installé 3 autre WS 8 DC avec la même configuration que celui-ci et ils n’ont jamais planté !!! Il fonctionne par contre avec une version de firmware 1.4.2 dois-je faire la mise à jour ??? J’ai peur :???:

Merci pour votre aide
Attachments
MAC ADRESS WSDC.PNG

Julian
 

Re: WS-8-150DC BLACKOUT

Sat Apr 08, 2017 9:09 am

The update doesn't have anything to do with your issue, sir.

Taking your switch out of the chassis decreases airflow and reliability, but hey, if it works for you, good.

Having the camera disabled will very likely mask your issue. In my testing here, I found that a certain percentage of units from a manufacturing run would start to go unstable after plugging x amount of cables in, removing one would return the system to stability.

Please email me your address, I will send you a kit with instructions on Monday.