v1.4.7rcX Bug Reports and Comments

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
Eric Stern
Employee
Employee
 
Posts: 532
Joined: Wed Apr 09, 2014 9:41 pm
Location: Toronto, Ontario
Has thanked: 0 time
Been thanked: 130 times

Re: v1.4.7rcX Bug Reports and Comments

Fri Apr 07, 2017 9:55 am

A small bug crept into rc17, I'll release rc18 to fix it.

IntL-Daniel
Experienced Member
 
Posts: 170
Joined: Mon Nov 02, 2015 5:07 pm
Location: Czech Republic
Has thanked: 7 times
Been thanked: 9 times

Re: v1.4.7rcX Bug Reports and Comments

Fri Apr 07, 2017 10:00 am

Why we are o RCs instead of betas?

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.7rcX Bug Reports and Comments

Fri Apr 07, 2017 10:30 am

IntL-Daniel wrote:Why we are o RCs instead of betas?


Because this is what we started with as far as release numbers.

I am sanity testing rc18 and will push it out here in the next hour or so.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
lligetfa
Associate
Associate
 
Posts: 1191
Joined: Sun Aug 03, 2014 12:12 pm
Location: Fort Frances Ont. Canada
Has thanked: 307 times
Been thanked: 381 times

Re: v1.4.7rcX Bug Reports and Comments

Fri Apr 07, 2017 10:46 am

IntL-Daniel wrote:Why we are o RCs instead of betas?
The betas are kept private.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

v1.4.7rc18 Released

Fri Apr 07, 2017 10:54 am

- Fixed STP tab on 12 port models - RC18

v1.4.7rcX wrote:NOTE: MSTP is still being tested so use MSTP at your own risk.

FIXED/CHANGED
- Fixed temp sensors showing crazy values in very cold environments - RC3
- Fixed getting "unexpected link change" messages due to port bounce, watchdogs, etc - RC3
- Fixed port bounce being 1 hour off after daylight savings time changes - RC3
- Fixed VLAN tab layout getting messed up when you delete a VLAN - RC3
- Fixed mac table refresh button causing entire page to reload - RC3
- Fixed problem with QinQ when using untagged VLANs - RC3
- Fixed fan control handling negative temperatures - RC4
- Fixed input voltage graph labels - RC4
- Fixed Apply/Save becoming active when looking at MSTP configuration even though nothing changed - RC6
- Fixed port number in log messages - RC6
- Fixed issue when importing config from a RevE board to a RevF with different POE port options. Affected WS-6 and WS-12 - RC6
- Fixed the support for WS-8-150-AC - RC7
- Fixed console login
- Fixed/Force powerdown/powerup limits on WS-8-150-DC to help prevent switch lock up when draining battery to 9V - RC8
- Fixed DC2DC-500 detection for WS-26-500-DC - RC8
- Fixed voltage range on dumb DC models - RC8
- Fixed QinQ - RC9
- Fixed VLAN trunking - RC9
- Fixed Access Controls not honouring the Enable setting - RC11
- Fixed switch rebooting if multiple ports lose link too quickly - RC14
- Fixed multiple ports not turning off at the same time when they have the same shutdown voltage - RC14
- Fixed unexpected link change speed message - RC14
- Fixed port selection Tabs - RC14
- Fixed slight glitch in Input Current graph - RC16
- Fixed STP tab on 12 port models - RC18
- Allow QinQ and Double Tagging to be used with Trunk ports - RC9
- Changed UI layout on QOS tab - RC3
- Changed dumb DC models to temporarily disable POE when input voltage falls too low instead of disabling POE in the configuration - RC3
- Changed valid DC input voltage range to 9-72V in GUI for newer board revs - RC3
- Changed valid upper range for dc output voltage from 51V to 53V - RC3
- Changed input voltage graph to auto-scale - RC3
- Changed fan control to also use CPU and PHY temp - RC6
- Changed valid temp range on Status page meters - RC6
- Changed input voltage threshold where it forgets the configured Wake up voltage and defaults to 10V Wake up on WS-12-250-DC - RC10

ENHANCEMENTS
- Added MSTP - RC3
- Automatically disable flow control on ports using QOS bandwidth limits to prevent packet locks - RC3
- Added restart timer to DC power supply to help in very cold environments with cold starts - RC3
- Added log message when time is set by NTP after boot is finished - RC3
- Added logging when STP selects new root port - RC3
- Added POE startup delay option on Power tab - RC3
- Added root path cost on STP tab - RC3
- Added portDuplex SNMP stat from CISCO-STACK-MIB - RC3
- Added ifAdminStatus to SNMP stats - RC3
- Added support for new WS-26 models - RC6
- Added Double Tagged to VLAN configuration - RC6
- Added IP Protocol to QoS rules - RC11
- Added CIDR notation in QoS Source IP rules - RC11
- Added option to log web and ssh logins - RC11
- Added LLDP-MIB and CISCO-CDP-MIB to SNMP - RC 14
- Added option to change MAC aging time - RC14
- Added "Disable Power" action to watchdog - RC16

KNOWN ISSUES
- Some language templates need help - please contact us to help

RC3 Released 1/3/2017
RC4 Released 1/3/2017
RC6 Released 1/26/2017
RC7 Released 1/27/2017
RC8 Released 2/7/2017
RC9 Released 2/16/2017
RC10 Released 2/20/2017
RC11 Released 2/22/2017
RC14 Released 3/7/2017
RC16 Released 4/4/2017
RC18 Released 4/7/2017
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
KBrownConsulting
Member
 
Posts: 71
Joined: Wed Dec 14, 2016 3:29 pm
Has thanked: 15 times
Been thanked: 17 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Apr 11, 2017 5:24 pm

Trivial issue: The Copyright info at the bottom of the web GUI still says: "Copyright 2014-2016 Netonix"

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: v1.4.7rcX Bug Reports and Comments

Tue Apr 11, 2017 5:43 pm

thanks....

ftxsteve
Member
 
Posts: 9
Joined: Mon Nov 02, 2015 8:29 pm
Has thanked: 1 time
Been thanked: 0 time

Re: v1.4.7rcX Bug Reports and Comments

Mon Apr 24, 2017 1:21 pm

You've still got a bug in VLAN operation on the latest software.
I have port 2 and 3 set up identically on the 6-port switch. On my OLT, port 5 sends VLANs 102 and 152. Port 6 sends port 201. When 5 connects to 2, only VLANs 102 and 152 work. OLT port 6 is connected to Netonix port 3. VLAN201 does not work in this scenario. When I swap the cables for the ports (2 to 3 and 3 to 2), only VLAN 201 works.

All I am doing is a simple cable swap at the Netonix.

I've tried this same test with ports 2 and 6 on the Netonix with the same result.

No changes were made in the OLT or the upstream router. The only thing that was done was reverse the cables at the mini-6.
Attachments
Netonix bug 2.jpeg
Netonix bug 1.jpeg

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.7rcX Bug Reports and Comments

Mon Apr 24, 2017 2:30 pm

Why do you have Ports 2 and 3 set to pass all VLAN IDs with "Port Trunk/Allowed VLANs"?

Also are you giving it time for the MAC tables to clear and update?

I am pretty sure this is NOT a big as this would be a MAJOR VLAN bug causing all sorts of people problems including me.

You do understand that every switch port has a difference MAC address and is another Layer 2 hop in the chain.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
Dawizman
Experienced Member
 
Posts: 141
Joined: Fri Jul 03, 2015 4:11 pm
Location: Cold Lake, AB - CANADA
Has thanked: 15 times
Been thanked: 22 times

Re: v1.4.7rcX Bug Reports and Comments

Mon May 01, 2017 12:16 pm

Any release notes on the rc19+ firmware? Just wondering what changes have been made other than compatibility for the WS-26 switches.

Thanks.

PreviousNext
Return to Hardware and software issues

Who is online