Ports 11 and 12 dropped link today.
Power enabled no ethernet link.
Log shows warnings of low 24v rail and two fans offline.
AF5x from port 12 now in port 10.
- Code: Select all
Pair 1 Status (Pins 1,2) (Pos) (Orange) Open
Pair 2 Status (Pins 3,6) (Neg) (Green) Ok
Pair 3 Status (Pins 4,5) (Pos) (Blue) Open
Pair 4 Status (Pins 7,8) (Neg) (Brown) Ok
Pair 1 Length 78.74 ft / 24 m
Pair 2 Length 620.07 ft / 189 m
Pair 3 Length 78.74 ft / 24 m
Pair 4 Length 620.07 ft / 189 m
Bad cable or end.
Rocket M2 in port 11 showed ok, ok, don't remember, don't remember, abnormal termination. Length was about right. Did not power on in port 7. Put it on PoE. Turned off power to port 11 and 12. Both devices link properly in port 11 and 12 while running on UBNT PoE.
Measured voltage on port 7 1.7 to 1.8 v
- Code: Select all
May 15 10:35:07 init: starting pid 281, tty '/dev/ttyS0': '/bin/ash --login'
May 15 10:35:07 Port: link state changed to 'down' on port 11
May 15 10:35:07 STP: set port 11 to discarding
May 15 10:35:07 Port: link state changed to 'down' on port 12
May 15 10:35:07 STP: set port 12 to discarding
May 15 10:35:12 switch[888]: 24V is out of range (21.5V)
May 15 10:36:06 switch[888]: Fan 2 is failing (0 RPM, cooling level 255, board temp 40 C)
May 15 10:36:07 switch[888]: Fan 3 is failing (0 RPM, cooling level 255, board temp 40 C)
May 15 12:17:13 UI: Configuration changed by admin (64.250.43.70)
May 15 12:17:13 UI: Port 11 PoE: changed from '24V' to 'Off'
May 15 12:17:29 UI: Configuration changed by admin (64.250.43.70)
May 15 12:17:29 UI: Port 11 PoE: changed from 'Off' to '24V'
May 15 12:17:34 switch[944]: PoE enabled on port 11, PoE Smart is starting cable check
May 15 12:17:39 switch[944]: Port 11 cable check results: Ok, Ok, Abnormal termination, Abnormal termination
May 15 12:17:39 switch[944]: Port 11 passed PoE Smart cable check, turning on power
May 15 12:25:06 UI: Configuration changed by admin (64.250.43.70)
May 15 12:25:06 UI: Port 7 PoE: changed from 'Off' to '24V'
May 15 12:25:06 UI: Port 11 PoE: changed from '24V' to 'Off'
May 15 12:25:06 UI: Port 12 PoE: changed from '24V' to 'Off'
May 15 12:25:11 switch[944]: PoE enabled on port 7, PoE Smart is starting cable check
May 15 12:25:16 switch[944]: Port 7 cable check results: Ok, Ok, Abnormal termination, Abnormal termination
May 15 12:25:16 switch[944]: Port 7 passed PoE Smart cable check, turning on power
May 15 12:42:14 Port: link state changed to 'up' (1G) on port 5
May 15 12:42:14 STP: set port 5 to discarding
May 15 12:42:14 STP: set port 5 to learning
May 15 12:42:14 STP: set port 5 to forwarding
May 15 13:12:23 Port: link state changed to 'up' (100M-F) on port 11
May 15 13:12:23 STP: set port 11 to discarding
May 15 13:12:25 STP: set port 11 to learning
May 15 13:12:25 STP: set port 11 to forwarding
May 15 13:50:57 Port: link state changed to 'up' (1G) on port 12
May 15 13:50:58 STP: set port 12 to discarding
May 15 13:50:58 switch[3437]: unexpected link change on port 12 (APs Bob Hambuchen) from F to 1G
May 15 13:51:00 STP: set port 12 to learning
May 15 13:51:00 STP: set port 12 to forwarding
May 15 13:51:18 Port: link state changed to 'down' on port 12
May 15 13:51:18 STP: set port 12 to discarding
May 15 13:51:20 Port: link state changed to 'up' (1G) on port 12
May 15 13:51:20 STP: set port 12 to discarding
May 15 13:51:22 STP: set port 12 to learning
May 15 13:51:22 STP: set port 12 to forwarding
Port 5 is WS-12-250-DC to which I am going to attempt to move the backhauls and APs. Port 13-24 are in building wifi and cameras. I don't care if they drop during testing.