Hi
have 2 pice of WS-8-150-DCthat reboot
after 2 hour or it can run a day ???
there is no watchdog on
it use about 30W
power 5 port with 24V and 1 whit 48v 0,75A
firmware ver. 1.4.7
have 7 running without a problem and with lower firmware
hope someone have a ide
WS-8-150-DC reboot
- thelli80
- Member
- Posts: 3
- Joined: Wed Oct 12, 2016 8:19 am
- Has thanked: 0 time
- Been thanked: 0 time
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: WS-8-150-DC reboot
Sound like it could be defect units possibly the 3.3V CAP issue described in several posts a while ago.
Please RMA the units and let us check them out.
Please RMA the units and let us check them out.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
- thelli80
- Member
- Posts: 3
- Joined: Wed Oct 12, 2016 8:19 am
- Has thanked: 0 time
- Been thanked: 0 time
Re: WS-8-150-AC reboot
Sorry this is the WS-8-150-AC model not DC
sorry for the wrong mistake
sorry for the wrong mistake
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: WS-8-150-DC reboot
Same answer, a small percentage of the WS-6 and WS-8 models were all possibly affected by 3.3V CAP issue in a previous batch.
Please RMA the units and let us check them out.
Please RMA the units and let us check them out.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
- thelli80
- Member
- Posts: 3
- Joined: Wed Oct 12, 2016 8:19 am
- Has thanked: 0 time
- Been thanked: 0 time
- dgerlach@disquom.de
- Member
- Posts: 29
- Joined: Mon Oct 19, 2015 9:00 am
- Has thanked: 0 time
- Been thanked: 2 times
Re: WS-8-150-DC reboot
we have the same Problem, what is the3.3V CAP Problem?
thx
thx
- Julian
Re: WS-8-150-DC reboot
It generally presents as the device rebooting after an amount of time. I can provide a full technical rundown of the failure, that may be beyond the scope of this thread, however.
We repair this for free, just use the conventional RMA process, found here: http://forum.netonix.com/viewtopic.php?f=6&t=1259.
In international cases such as yours, we can also provide replacement components and instructions at no charge, if you're comfortable attempting the rework yourself, and have facilities at your disposal to do so.
If you'd prefer the second option, send me an email using the link to the right of this post, and I will get it on the way as soon as possible.
We repair this for free, just use the conventional RMA process, found here: http://forum.netonix.com/viewtopic.php?f=6&t=1259.
In international cases such as yours, we can also provide replacement components and instructions at no charge, if you're comfortable attempting the rework yourself, and have facilities at your disposal to do so.
If you'd prefer the second option, send me an email using the link to the right of this post, and I will get it on the way as soon as possible.
- wifi442
- Member
- Posts: 18
- Joined: Fri Aug 21, 2015 11:16 am
- Location: Southern CA
- Has thanked: 0 time
- Been thanked: 6 times
Re: WS-8-150-DC reboot
Is there any chance this problem could affect the new WS-26-500-DC Models? I have one installed indoors where there used to be two WS-12-250-DC Models that ran smooth with almost 6 months of uptime. This one is rebooting about every 2-3 days. Sometimes it lasts longer. The uptime on the switch resets and also all of the devices connected show the same uptime.
Running 1.4.8rc7 FW
Thanks
Jason
Running 1.4.8rc7 FW
Thanks
Jason
- Julian
Re: WS-8-150-DC reboot
wifi442 wrote:Is there any chance this problem could affect the new WS-26-500-DC Models? I have one installed indoors where there used to be two WS-12-250-DC Models that ran smooth with almost 6 months of uptime. This one is rebooting about every 2-3 days. Sometimes it lasts longer. The uptime on the switch resets and also all of the devices connected show the same uptime.
Running 1.4.8rc7 FW
Thanks
Jason
Hi Jason. Do you have any metrics available for this? I'm interested in: Board 48V, Board Temperature, Power supply temperature, power supply controller temperature.
You may need to RMA - I have seen an as-yet-undiagnosed hardware failure cause the 500-DC to become unstable, but let's not jump the gun.
9 posts