WS-12-250-DC

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
kdsnetworks
Member
 
Posts: 13
Joined: Fri Sep 25, 2015 10:58 pm
Location: Great Falls, MT
Has thanked: 0 time
Been thanked: 0 time

WS-12-250-DC

Tue May 30, 2017 8:22 pm

Temperature ports shutdown.

Running version 1.4.6 / F / 46/ B

For some reason i started to get ports shutdown due to overheating. We have today 89F - inside the box was about 110F
My question is what are the values at which the temps for the switch are too high and the system will start shutting down ports.
BTW the system log did not log the events. I was just watching the switch wondering what is going on and based on the priotity the switch started to turn off ports for like 25sec to about a minute.

This is my temp values. BTW I have an older unit ... AC version that is WAY hotter sits in a metal box - with board Temp close to 79C and I have absolutely no issues.

Would this revision be a special one ? BTW fan is going just fine at about 8k

Board Temp
125 C
58
-25 C
CPU Temp
125 C
80
-25 C
PHY Temp
125 C
83
-25 C
Power Supply Board Temp
125 C
52
-25 C
Power Supply Heatsink #1 Temp
125 C
48
-25 C
Power Supply Heatsink #2 Temp
125 C
48
-25 C
Power Supply Controller Temp
125 C
73
-25 C

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-12-250-DC

Tue May 30, 2017 10:10 pm

Read release notes and you would see there was a fix in v1.4.8rcX for the DC switches

Please, when you have an issue read the release notes then upgrade to the LATEST version and see if the problem is still there
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
kdsnetworks
Member
 
Posts: 13
Joined: Fri Sep 25, 2015 10:58 pm
Location: Great Falls, MT
Has thanked: 0 time
Been thanked: 0 time

Re: WS-12-250-DC

Wed May 31, 2017 11:32 am

I saw the dc had some issues with power but was not sure if the temps was related to it as well .. Thx will push the latest and we will see

Return to Hardware and software issues

Who is online