We are starting to deploy 24v and 48v DC power at our Broadcast sites with our Netonix 250 DC switches.. can people post pics of their DC setups? Trying to get ideas of what works best in various space constraints.
We are planning on using the Ubnt EdgePower at the ground feeding 48v up the tower where our netonix switch is located. I have (4) Optima Blue top batteries, what are the recommendations for a battery charger?
Thanks!
Jordan
DC Power Setup at Tower Sites
-
jsmithkc0512 - Member
- Posts: 7
- Joined: Sun Dec 27, 2015 1:44 pm
- Location: South Florida, and the Keys
- Has thanked: 0 time
- Been thanked: 0 time
-
mike99 - Associate
- Posts: 837
- Joined: Tue Nov 25, 2014 10:53 am
- Location: Quebec, Canada
- Has thanked: 95 times
- Been thanked: 245 times
Re: DC Power Setup at Tower Sites
Huawei ETP4830 or Vertiv Netsure 200 serie. Both have dual redondant power supply + battery charger + control board + 48V DC output (20A output + 10A output).
- abdoudia
- Member
- Posts: 12
- Joined: Tue Nov 29, 2016 10:00 pm
- Location: Burkina Faso
- Has thanked: 0 time
- Been thanked: 1 time
Re: DC Power Setup at Tower Sites
Any online store in the us where we can get them?
-
sirhc - Employee
- Posts: 7422
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1609 times
- Been thanked: 1326 times
Re: DC Power Setup at Tower Sites
Well if you are using a power supply you should use the WS-12-DC not the WS-12-250-DC.
The WS-12-250-DC is designed to hook directly to battery banks.
WHy do want to use the EdgePower?
If you are going to put the WS-12-250-DC on the tower connect directly to battery bank and use a smart charger like the Minn Kota chargers which come in 1 through 4 battery bank.
They charge each battery separately so you can hook the batteries in series and have 48V battery bank.
I would not use the EdgePower, why?
https://www.google.com/search?q=minn+ko ... s&tbm=shop
The WS-12-250-DC is designed to hook directly to battery banks.
WHy do want to use the EdgePower?
If you are going to put the WS-12-250-DC on the tower connect directly to battery bank and use a smart charger like the Minn Kota chargers which come in 1 through 4 battery bank.
They charge each battery separately so you can hook the batteries in series and have 48V battery bank.
I would not use the EdgePower, why?
https://www.google.com/search?q=minn+ko ... s&tbm=shop
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
5 posts
Page 1 of 1
Who is online
Users browsing this forum: No registered users and 61 guests