WS-12-250-AC No traffic !!

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
quadra
Experienced Member
 
Posts: 143
Joined: Sat Oct 31, 2015 8:25 am
Location: France
Has thanked: 3 times
Been thanked: 2 times

WS-12-250-AC No traffic !!

Wed Jul 12, 2017 9:19 am

Hi everybody
I have a strange worry about port No. 1 on a WS-12-250-AC
When I activate the POE 48 V and I connect my camera I have the voltage but no traffic "green LED" !!! So I figured my wiring was bad! :pissed:
But curiously when I plug in POE 48 V on port 2 3 4 5 6 7 ....... Everything works well !!!! :screwb:
If I just connect a PC to port # 1 it works the green LED is on! .... :screwb: :screwb:
Really bizarre what to do to repair this port ??? :?:

Julian
 

Re: WS-12-250-AC No traffic !!

Wed Jul 12, 2017 9:30 am

it can have to do with the length of the cable used - a stressed transformer might not attain a link with a longer cable, but will work okay with a short cable.

What do cable diagnostics on that port say with nothing plugged in?

User avatar
quadra
Experienced Member
 
Posts: 143
Joined: Sat Oct 31, 2015 8:25 am
Location: France
Has thanked: 3 times
Been thanked: 2 times

Re: WS-12-250-AC No traffic !!

Wed Jul 12, 2017 12:29 pm

Salut julian

je vais regarder je te tiens au courant

mais la longueurs est d'environ 25 mètres 30 mètres .... j'ai déjà fais du 80 mètres en POE en du netonix et sans problème :thumbsup:

merci

Julian
 

Re: WS-12-250-AC No traffic !!

Wed Jul 12, 2017 12:51 pm

the green LED means that the physical interfaces can each 'see' down the cable to the other end, and can signal each other as necessary to communicate at the set line speed.

To carry the metaphor further, if the physical interface on the switch's side gets a poke in the eye from a static spike or something, sometimes it will 'squint', rather than keeping it's eye all the way open- this will leave it unable to 'see' the entire way down the cable.. The physical interfaces will attempt to negotiate a lower line speed, and if unable to, you won't get a link on that port.

You should have no trouble getting a link at even 100m, with a properly functioning system - my assumption, here, backed by what you're telling me, is that something isn't working correctly. This is why the question about cable diagnostics with nothing plugged in - which you missed answering :)

User avatar
quadra
Experienced Member
 
Posts: 143
Joined: Sat Oct 31, 2015 8:25 am
Location: France
Has thanked: 3 times
Been thanked: 2 times

Re: WS-12-250-AC No traffic !!

Tue Jul 18, 2017 11:25 pm

Hello
So I repeated several attempts, changed the cable but it is always the same ...
On port 1 in POE 48V no traffic "green led" and I take this same cable on port 2 POE 48 V and it works very well .... :screwb:
It's really weird :shock:

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-12-250-AC No traffic !!

Wed Jul 19, 2017 1:26 am

Bench test the switch, instructions here: viewtopic.php?f=6&t=2780
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.