poe "soft start"
poe "soft start"
Might it be considered that a "soft start" function be implemented on the poe power outputs ,whereas the power applied to the poe output would be administered over a few milliseconds as opposed to an "instant on". There would be benefits to such a feature.
-
sirhc - Employee
- Posts: 7415
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: poe "soft start"
gryeden wrote:Might it be considered that a "soft start" function be implemented on the poe power outputs ,whereas the power applied to the poe output would be administered over a few milliseconds as opposed to an "instant on". There would be benefits to such a feature.
Not sure I follow you?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
lligetfa - Associate
- Posts: 1191
- Joined: Sun Aug 03, 2014 12:12 pm
- Location: Fort Frances Ont. Canada
- Has thanked: 307 times
- Been thanked: 381 times
Re: poe "soft start"
Since there is possible inrush current, I would think you would actually want the opposite of a soft start so as to get the voltage up as quickly as possible to reduce the current. The polyfuses are thermal in nature so getting past the inrush sooner means they are less likely to get hot. So too, the Ethernet transformers.
-
sirhc - Employee
- Posts: 7415
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: poe "soft start"
There is a STAGGER or delay between powering up all the ports.
So if your turning on 4 ports it turns 1 on at a time waiting 0.5 seconds before turning up the next port.
So if your turning on 4 ports it turns 1 on at a time waiting 0.5 seconds before turning up the next port.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Re: poe "soft start"
While I was working in GM development lab , it was found that "cold" loads actually exceed current draw momentarily when power was applied. We solved the issue with a soft start feature. Ever notice that when you flip a light switch , that is when the bulb is most likely to burn out. Because the filament is cold , the surge current exceeds the bulbs ability to dissipate the heat , and poof.