Eric Stern - Employee
- Posts: 532
- Joined: Wed Apr 09, 2014 9:41 pm
- Location: Toronto, Ontario
- Has thanked: 0 time
- Been thanked: 130 times
Re: BOARD INDEX / WISP SWITCH™ / HARDWARE AND SOFTWARE ISSUE
Can't duplicate the problem, must be the SFPs.
- bill.vincent
- Member
- Posts: 7
- Joined: Wed Dec 30, 2015 6:19 pm
- Has thanked: 0 time
- Been thanked: 0 time
Re: BOARD INDEX / WISP SWITCH™ / HARDWARE AND SOFTWARE ISSUE
Gentleman
This morning I have been trying some other sfp's to see if they work.
And I have found something very interesting. I found that after setting a mtu setting in the switch if I remove and then reinstall the sfp it starts working
if I am changing from 1528 to 9600 with sfp already installed I do not pass any traffic ( all packet sizes) until I remove and reinstall sfp back into port on switch and then I am able to pass all packet sizes including jumbo packets.
If I am changing from 9600 to 1528 with sfp already installed I do not pass any traffic ( all packet sizes) until I remove and reinstall sfp back into port on switch and then I am able to pass all packet sizes except for jumbo packets, which I would expect.
for some reason sfp has to be removed and reseated before starting to pass traffic.
when I was testing before and I would set mtu setting back ( after failing to work at 9600) to 1528 on the active port that needs to pass jumbo packets. I would have to reboot switch to get my traffic flowing again.
All three of these sfp models exhibit the same results.
PAC Opto model LM28-C35-TC-N
GTS8510-MC
Alcatel Lucent model#3HE00027CA 01 / MFGR: Finisar MFGR P/N FTLF8519P3BTL-AS
This morning I have been trying some other sfp's to see if they work.
And I have found something very interesting. I found that after setting a mtu setting in the switch if I remove and then reinstall the sfp it starts working
if I am changing from 1528 to 9600 with sfp already installed I do not pass any traffic ( all packet sizes) until I remove and reinstall sfp back into port on switch and then I am able to pass all packet sizes including jumbo packets.
If I am changing from 9600 to 1528 with sfp already installed I do not pass any traffic ( all packet sizes) until I remove and reinstall sfp back into port on switch and then I am able to pass all packet sizes except for jumbo packets, which I would expect.
for some reason sfp has to be removed and reseated before starting to pass traffic.
when I was testing before and I would set mtu setting back ( after failing to work at 9600) to 1528 on the active port that needs to pass jumbo packets. I would have to reboot switch to get my traffic flowing again.
All three of these sfp models exhibit the same results.
PAC Opto model LM28-C35-TC-N
GTS8510-MC
Alcatel Lucent model#3HE00027CA 01 / MFGR: Finisar MFGR P/N FTLF8519P3BTL-AS
- bill.vincent
- Member
- Posts: 7
- Joined: Wed Dec 30, 2015 6:19 pm
- Has thanked: 0 time
- Been thanked: 0 time
Re: BOARD INDEX / WISP SWITCH™ / HARDWARE AND SOFTWARE ISSUE
problem solved.
applied mtu setting to each fiber port, reseated each sfp and all tests good.
Thanks for the Help
applied mtu setting to each fiber port, reseated each sfp and all tests good.