Julian wrote:The fact that it lasted 4 months leads me towards the idea that there may be some other issue at work here, but I won't know until I get a first-hand look. I take it
there were no other changes to your deployment, I.E. you didn't plug anything else in or make any configuration changes?
There were not any changes to the deployment. It recently has gotten colder and the switch is in an outdoor box. The temp here the last few days has been colder in the 40deg range. The switch connected to UPS for power, but nothing else on the same UPS - WS-12-250-AC, Mtik Router, Airfiber5X - rebooted. Switch is powered using the barrel connector and not the PoE in port.
Basically I got interface flapping notifications from my Mikrotik router at the tower and after the port stopped flapping the switch showed it had just rebooted along with all the APs powered by the switch.
It happened at 3:12pm, 3:13pm, 3:21pm, 3:49pm until I replaced just the switch at 4:10pm yesterday.
Sometimes the router would show the port flapping a couple of times which looks like a boot sequence.
Other times it would maybe flap twice as much before the switch rebooted.
I will fill out an RMA form and get it sent back. Based on this what do you think some of the possible causes could be?