Hi,
I have no free 48VH ports in my WS-10-250-AC. I needs to power a WS-6-MINI, so I connected it with 48 V.
I seems to work, but will it be stable or is it a no go ? (Plan is to upgrade WS-10-250-AC to WS-12-250-AC as it has 4 pcs. 48VH ports).
I will need to power 3 pcs. Rocket AC Prism Gen2 (24V) and 1 pcs. UniFi Outdoor (48V)....
I have 2 of the 3 Rocket AC Prism Gen2 turned on now.
Current power usage....
Will I run into problems ?
Powering WS-6-MINI from WS-10-250-AC with 48V
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Powering WS-6-MINI from WS-10-250-AC with 48V
The difference between 48V and 48VH is that 48V only uses 2 pair to deliver power verses 48VH which uses all 4 pair.
SO this puts a strain on the Ethernet Transformer and there is more resistance trying to push current on 4 wires verses all 8 wires.
Can damage the Ethernet Transformer on either the WS-10 and or the WS-6
48V is rated at 38 watts because it uses only 2 pair to carry current
48VH is rated at 75 watts because it uses all 4 pair to carry current
Assume a peak/max of 12 watts for each of those 3 radios you want to power so 3 x 12 - 36 watts + 4 to 6 watts for WS-6 = 42 watts
Do not forget cable loss - your right on the edge and may encounter radio reboots if current drops
This is a good post to read, and then read again:
viewtopic.php?f=6&t=1178#p8809
SO this puts a strain on the Ethernet Transformer and there is more resistance trying to push current on 4 wires verses all 8 wires.
Can damage the Ethernet Transformer on either the WS-10 and or the WS-6
48V is rated at 38 watts because it uses only 2 pair to carry current
48VH is rated at 75 watts because it uses all 4 pair to carry current
Assume a peak/max of 12 watts for each of those 3 radios you want to power so 3 x 12 - 36 watts + 4 to 6 watts for WS-6 = 42 watts
Do not forget cable loss - your right on the edge and may encounter radio reboots if current drops
This is a good post to read, and then read again:
viewtopic.php?f=6&t=1178#p8809
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
lligetfa - Associate
- Posts: 1191
- Joined: Sun Aug 03, 2014 12:12 pm
- Location: Fort Frances Ont. Canada
- Has thanked: 307 times
- Been thanked: 381 times
Re: Powering WS-6-MINI from WS-10-250-AC with 48V
You don't actually show the current usage, just the voltage drop. It is not the voltage that is of concern but rather the current.
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Powering WS-6-MINI from WS-10-250-AC with 48V
lligetfa wrote:You don't actually show the current usage, just the voltage drop. It is not the voltage that is of concern but rather the current.
Exactly and since the voltage was 50V when it left the WS-10 and is only 45V at the WS-6 this is telling your that you have cable drop of 5V which would be less if using all 8 wires with 48VH instead of just 4 wires with 48V.
The more current you draw through the 2 pair (4 wires) the more voltage drop you will see which is loss and this is putting a strain on the center taps of the Ethernet Transformers.
Think of it this way, if you supplied water to a house with a single 1/2 inch pipe versus two 1/2 inch pipes. You would not notice a difference if you only used one faucet at a time in the house with just a single 1/2 inch pipe but if you tried to take a shower while someone washed their hands and another person flushed a toilet you would notice a significant drop in water pressure whereas the house getting water with two 1/2 inch pipes the pressure drop would be significantly less.
I would replace that WS-10 as soon as possible with a WS-12 and switch to 48VH to power the WS-6
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
lligetfa - Associate
- Posts: 1191
- Joined: Sun Aug 03, 2014 12:12 pm
- Location: Fort Frances Ont. Canada
- Has thanked: 307 times
- Been thanked: 381 times
Re: Powering WS-6-MINI from WS-10-250-AC with 48V
sirhc wrote:Exactly and since the voltage was 50V when it left the WS-10 and is only 45V at the WS-6 this is telling your that you have cable drop of 5V...
Input diodes on the WS-6 will cause a 1.4V drop so cable drop is only 3.6V which is not that bad. Of course the unknown factor is cable length and/or wattage draw. I've seen 41.9V on a heavily loaded MINI and the cable was eating 10W.
-
jjonsson - Associate
- Posts: 337
- Joined: Wed Nov 05, 2014 12:30 pm
- Location: Denmark
- Has thanked: 37 times
- Been thanked: 65 times
Re: Powering WS-6-MINI from WS-10-250-AC with 48V
sirhc wrote:
I would replace that WS-10 as soon as possible with a WS-12 and switch to 48VH to power the WS-6
That's the plan within a month...
Unfortunately getting Netonix switches in Scandinavia is very difficult. Winther Wireless is often low on stock. And why You didn't manage to get a deal with AVD is still strange to me.....
Both are reporting difficulties to get Netonix switches. I know there's a huge demand. People just can't wait, so they buy something else.....
We're a least 5 wISP in Denmark using Netonix (And probably more). I know some who would like to start using Netonix. But current situation on stock is unsustainable, and not something new buyers will depend on...
-
Dave - Employee
- Posts: 726
- Joined: Tue Apr 08, 2014 6:28 pm
- Has thanked: 1 time
- Been thanked: 158 times
Re: Powering WS-6-MINI from WS-10-250-AC with 48V
Both are reporting difficulties to get Netonix switches. I know there's a huge demand. People just can't wait, so they buy something else.....
Chris will look into this, as we always have product that we can ship to your country, so the issue is not at our end....
-
jjonsson - Associate
- Posts: 337
- Joined: Wed Nov 05, 2014 12:30 pm
- Location: Denmark
- Has thanked: 37 times
- Been thanked: 65 times
Re: Powering WS-6-MINI from WS-10-250-AC with 48V
Dave wrote:Both are reporting difficulties to get Netonix switches. I know there's a huge demand. People just can't wait, so they buy something else.....
Chris will look into this, as we always have product that we can ship to your country, so the issue is not at our end....
Then I just can't understand why latest shipment to Winther took over 2 months ? I had backorder for over 2 months ???
I'm not sure who is not telling the true.
Strange is that both Winther and AVD have reported similar difficulties getting stock.
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Powering WS-6-MINI from WS-10-250-AC with 48V
jjonsson wrote:sirhc wrote:
I would replace that WS-10 as soon as possible with a WS-12 and switch to 48VH to power the WS-6
That's the plan within a month...
Unfortunately getting Netonix switches in Scandinavia is very difficult. Winther Wireless is often low on stock. And why You didn't manage to get a deal with AVD is still strange to me.....
Both are reporting difficulties to get Netonix switches. I know there's a huge demand. People just can't wait, so they buy something else.....
We're a least 5 wISP in Denmark using Netonix (And probably more). I know some who would like to start using Netonix. But current situation on stock is unsustainable, and not something new buyers will depend on...
Because the ball was left in AVD's court, I explained this the last time you asked, somewhere on here is a copy and paste of the last email exchange with them.
You can always buy direct?
Since you are an Associate you get 10% OFF but you lose shipping discount on less than 4 switches or login with a non discount account and we discount shipping is your order is 1 to 3 units.
With 4 or more switches in your cart use your Associate account and get discounted shipping plus your 10% Associate discount.
As you can see in the picture below using a non discount account (MSRP) shipping on 3 switches from US to Denmark with DHL Express 3 business day is only $38.36 which is like $12.79 each for EXPRESS Shipping????
If your local Distributor does not carry it then order it direct and it is there in 3 business days.
NOTE: You have to pay VAT Tax but you pay VAT Tax when buying from a reseller in your your country. THere are also several other Distributors in Europe.
CLICK IMAGE BELOW TO VIEW FULL SIZE
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
jjonsson - Associate
- Posts: 337
- Joined: Wed Nov 05, 2014 12:30 pm
- Location: Denmark
- Has thanked: 37 times
- Been thanked: 65 times
Re: Powering WS-6-MINI from WS-10-250-AC with 48V
sirhc wrote:Because the ball was left in AVD's court, I explained this the last time you asked, somewhere on here is a copy and paste of the last email exchange with them.
Maybe that's the case but I still hear similar story from Winther Wireless ? It took 2 months to get the switches I had in backorder ?
I don't have credit with Netonix. I do have credit at both AVD and Winther Wireless. That makes a huge difference from buying direct. Also if they had the switches on stock, I could order 1 or 2 when needed. Buying direct from you I have to order min. 6 if not freight and tax is eating it all up...
Who is online