v1.4.9 Bug reports and Comments

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

v1.4.9 Bug reports and Comments

Wed Dec 27, 2017 3:18 pm

Please post bug reports and comments on v1.4.9 ONLY in this thread.

v1.4.9 wrote:NOTE: IGMP snooping over VLANS, MSTP, and ERPS are still being developed so use these features at your own risk.

FIXED/CHANGED
- Fixed ubiquiti Discovery TAB with new ubiquiti firmware; not sure if this fixes where some have reported issues when doing a UBNT Discovery from a UBNT router causing issues with the Netonix switches?

- Fixed changing VLAN List in MSTP configuration
- Fixed MSTP root message
- Fixed to only show OCP controls if board has OCP

ENHANCEMENTS
- Added ifHighSpeed from IF-MIB
- Added option to enable both SNMP v1 and v2c

KNOWN ISSUES
- Loop Protection broken on SFP ports
- CPU utilization too high on WS-26-500-DC can cause reboots - will release v1.5.0rcX soon to fix this
- UI issues when not at 100% Zoom on browser.
- Some language templates need help - please private message Eric Stern to help
- IGMP snooping over VLANS, MSTP, and ERPS are still being developed

Released 12/27/2017
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

drbaker
Member
 
Posts: 5
Joined: Wed Aug 03, 2016 8:45 pm
Has thanked: 1 time
Been thanked: 0 time

Re: v1.4.9 Bug reports and Comments

Fri Dec 29, 2017 3:37 pm

Please take a look at this lab config. We are testing ERPS functionality before put it in production, but no resuts.

4 Netonix in ring topology, erps control seems to work fine, but vlans declared in vlan monitor field appears to be blocked for all switch ports, in all ERPS working modes. If somebody have a working config please let us know, thanks

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.9 Bug reports and Comments

Fri Dec 29, 2017 6:24 pm

drbaker wrote:Please take a look at this lab config. We are testing ERPS functionality before put it in production, but no resuts.

4 Netonix in ring topology, erps control seems to work fine, but vlans declared in vlan monitor field appears to be blocked for all switch ports, in all ERPS working modes. If somebody have a working config please let us know, thanks


mike99 and Eric are testing/developing this feature which is still being developed and classified as use at own risk.

Eric is on vacation for 10 days and mike99 has a day job so whenever he gets a chance.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
mike99
Associate
Associate
 
Posts: 837
Joined: Tue Nov 25, 2014 10:53 am
Location: Quebec, Canada
Has thanked: 95 times
Been thanked: 245 times

Re: v1.4.9 Bug reports and Comments

Sun Dec 31, 2017 11:33 am

I have test the feature and reported what seem a wrong behavior to Dave and Eric. I'm waiting for a new firmware to test.

jg0007
Member
 
Posts: 82
Joined: Wed Jan 20, 2016 2:07 am
Has thanked: 0 time
Been thanked: 7 times

Re: v1.4.9 Bug reports and Comments

Thu Jan 11, 2018 10:44 pm

I found a bug After the update I can not turn on a port ie enable it from OFF to 24 in the registered one but the switch does not power the port
Attachments
netonix 1.jpg

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.9 Bug reports and Comments

Thu Jan 11, 2018 11:23 pm

Please post up screen grabs of these TABs

Status
Ports
VLANs
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
sporkman
Member
 
Posts: 86
Joined: Mon Jul 27, 2015 7:03 pm
Location: New York, NY
Has thanked: 8 times
Been thanked: 11 times

Re: v1.4.9 Bug reports and Comments

Fri Jan 12, 2018 3:34 am

I'm on my second ws-6-mini at a site that had been stable for at least a year. I'm now seeing the switch just randomly stop passing traffic until it's power-cycled. It continues to power everything attached to it. Two things that changed are adding a radio (metrolinq 2.5-60-19) and upgrading from 1.4.8 to 1.4.9. I'm normally not someone that is an early adopter and prefer to let others find bugs, but I think I was here asking a question and just noticed 1.4.9 was out so I put it on two switches.

I know this is super broad and vague, but anyone else seeing this? I suspected hardware (hence the swap), but after a day and a half, another lockup. I'm going to downgrade to 1.4.8 and give it a few days. If that fixes it, anything I can provide?

Are there any plans in the future to carry logs across reboots?

jg0007
Member
 
Posts: 82
Joined: Wed Jan 20, 2016 2:07 am
Has thanked: 0 time
Been thanked: 7 times

Re: v1.4.9 Bug reports and Comments

Fri Jan 12, 2018 9:35 am

sirhc wrote:Please post up screen grabs of these TABs

Status
Ports
VLANs


Hi, here's the picture you asked me
Attachments
Screenshot_20180112-092549.png
Screenshot_20180112-092527.png
Screenshot_20180112-092517.png

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.9 Bug reports and Comments

Fri Jan 12, 2018 9:56 am

jg0007 wrote:I found a bug After the update I can not turn on a port ie enable it from OFF to 24 in the registered one but the switch does not power the port


You have red arrows pointing to port 2 and port 3 in your original post picture.

Port 2 has an X on it because it is disabled on the Ports TAB
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.4.9 Bug reports and Comments

Fri Jan 12, 2018 10:04 am

sporkman wrote:I'm on my second ws-6-mini at a site that had been stable for at least a year. I'm now seeing the switch just randomly stop passing traffic until it's power-cycled. It continues to power everything attached to it. Two things that changed are adding a radio (metrolinq 2.5-60-19) and upgrading from 1.4.8 to 1.4.9. I'm normally not someone that is an early adopter and prefer to let others find bugs, but I think I was here asking a question and just noticed 1.4.9 was out so I put it on two switches.

I know this is super broad and vague, but anyone else seeing this? I suspected hardware (hence the swap), but after a day and a half, another lockup. I'm going to downgrade to 1.4.8 and give it a few days. If that fixes it, anything I can provide?

Are there any plans in the future to carry logs across reboots?


Tell me any device that keeps a log after reboot?
This is why we support a syslog server.
viewtopic.php?f=17&t=1497&p=11096&hilit=+log+reboot+syslog#p11096

I highly doubt the switch "locked" up but rather this is a Pause Frame Packet Lock. There are TONS of posts discussing this on this forums and UBNT Forum. This is not a bug on our end but rather how wireless devices handle Pause Frames.
viewtopic.php?f=17&t=671&start=110#p22252

Search and read post on the forum about Flow Control. You can try disabling Flow Control on all ports if the problem persists to determine if that is your issue.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

Next
Return to Hardware and software issues

Who is online

Users browsing this forum: No registered users and 63 guests