Cleaning up my office I realized I've got a WS-12-250 that needs to be RMA'd.

My initial notes from July (hence the old FW :yikes: ) :
Symptoms: This was a spare switch still in the box.
Took it out yesterday to replace a WS-8 (needed more ports), upgraded to 1.4.7, configured, and put into production.
This morning I noticed it was rebooting. Acts like normal power up, but cuts out, fan sounds sick, eventually boots, then starts all over again.
Defaulted via button, now the fan comes on but doesn't boot any further - no lights, no ping.


MAC: EC:13:B2:61:DC:56
Purchased from: Netonix ORDER #145002483
Date purchased: 21-Nov-2016

Not sure if this is one with a cap issue or not.
Three of the ports were set to 24V and one was 48V
Put the WS-8 back and it has been working fine since.... now I need more ports again.

Let me know what I need to do next. Thanks-Jake

Julian
 

Re: WS-12-250-AC rebooting / dead

Thu Jan 11, 2018 3:41 pm

Jake -

This came out of the not-quite-right batch of power supplies we got - Open an RMA, will try to get your switch turned around pretty quickly.

Thanks,
Julian

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: WS-12-250-AC rebooting / dead

Thu Jan 11, 2018 3:43 pm

Thanks, Julian.

Will submit an RMA.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-12-250-AC rebooting / dead

Thu Jan 11, 2018 3:43 pm

There is a link on the footer of our web page with RMA instruction.

RMA.png
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
Chris@edgarhighspeed.com
Member
 
Posts: 58
Joined: Tue Nov 10, 2015 11:05 pm
Location: Red Deer, Alberta - CANADA
Has thanked: 4 times
Been thanked: 10 times

Re: WS-12-250-AC rebooting / dead

Mon Jan 15, 2018 6:29 pm

Hi Guys,
I am going to RMA this ws-12-205AC, I started another thread about firmware upgrade, perhaps it was the power supply crapping out and not the power cable. Can someone confirm if this switch came from the batch mentioned above.

MAC EC:13:B2:61:C3:58

I don't have a purchase date, it has been in stock a for a bit.

thanks,

Julian
 

Re: WS-12-250-AC rebooting / dead

Wed Jan 17, 2018 9:23 am

Can confirm that that power supply is from the defective batch. Really sorry for the inconvenience.

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: WS-12-250-AC rebooting / dead

Wed Jan 17, 2018 10:20 am

Julian wrote:Really sorry for the inconvenience.


Am sure Chris is breathing a sigh of relief... we've both had our share of weird things.
Must be he's been hanging around with me and my Irish luck too much :crazy:

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: WS-12-250-AC rebooting / dead

Thu Jan 25, 2018 10:07 am

Julian wrote:Jake -

This came out of the not-quite-right batch of power supplies we got - Open an RMA, will try to get your switch turned around pretty quickly.

Thanks,
Julian



Checking in on the status of the repair - no rush, just noticed the switch has been there a week a so.

Yes I sent it USPS :ak:
Haven't had a chance to setup UPS pickup since they closed the local office and it's an hour away now.

Thanks-Jake



JAN 16 Delivered
Netonix
9505516008978012164502
Delivered
Delivered, Garage or Other Location at Address
Jan 16, 2018 at 01:38 PM

Julian
 

Re: WS-12-250-AC rebooting / dead

Thu Jan 25, 2018 10:17 am

Will get you an email before the end of the week. Sorry, I've been out sick most of the last two weeks.

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: WS-12-250-AC rebooting / dead

Thu Jan 25, 2018 10:25 am

No worries, it sat in my office for more than 6 months needing an RMA so it's not urgent.