WS-12-250 - Fan Replacement

User avatar
danmanners
Member
 
Posts: 20
Joined: Tue Sep 01, 2015 2:53 pm
Location: Raleigh, NC
Has thanked: 1 time
Been thanked: 17 times

WS-12-250 - Fan Replacement

Sun Jan 14, 2018 3:22 pm

Hey everyone!
I've been using my original two units for my homelab environment and found that the fans really get loud and a bit annoying when they're running indoors in my office. Where I work 5-6 days a week. All the time.
Here's a quick Imgur gallery of steps and photos for what I did to replace my fans in two WS-12-250-AC units.

FULL DISCLOSURE: This will void your warranty, and I'm sure Sirhc will say that this is a bad idea (and he's probably right, lol).
That being said, I took the ambient volume from the switches from around ~35dB to ~19dB, and I'm very happy with the results. Board temp does not appear to have taken any hits, but will continue monitoring it.

Enjoy!

dm

User avatar
sirhc
Employee
Employee
 
Posts: 7421
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: WS-12-250 - Fan Replacement

Sun Jan 14, 2018 5:09 pm

Since you have the hood up then you might want to do this MOD
viewtopic.php?f=17&t=2584#p18081
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
jakematic
Experienced Member
 
Posts: 168
Joined: Thu Jul 14, 2016 8:15 am
Location: NC USA
Has thanked: 362 times
Been thanked: 87 times

Re: WS-12-250 - Fan Replacement

Mon Jan 15, 2018 8:37 am

danmanners wrote:I've been using my original two units for my homelab environment and found that the fans really get loud and a bit annoying when they're running indoors in my office. Where I work 5-6 days a week. All the time.


Ironically I use my WS-12-250s to mark the change in season - right now I can't wait for the fan noise again :yikes:

Funny story... the fans seemed to be running an awful lot this autumn and my office seemed a little warmer than normal.
Sure enough my heatpump was on the fritz. LOL

User avatar
danmanners
Member
 
Posts: 20
Joined: Tue Sep 01, 2015 2:53 pm
Location: Raleigh, NC
Has thanked: 1 time
Been thanked: 17 times

Re: WS-12-250 - Fan Replacement

Mon Jan 15, 2018 10:34 am

sirhc wrote:Since you have the hood up then you might want to do this MOD
http://forum.netonix.com/viewtopic.php? ... 584#p18081


Awesome, I very well may do that soon! Thanks man!

(Also, long time no chat, hope you've been well and that you had a great new year!)

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: WS-12-250 - Fan Replacement

Mon Jan 15, 2018 11:21 am

Also, as a note on your fan replacement...the fan you chose will be fine for a climate controlled office, but possibly not (depending on install location, etc) for the real non-environmentally controlled WISP environment.

Your replacement fan is indeed much quieter, but can also only push 5.9 CFM's of air, while our production fan can push 10.8 CFM's. Basically, most fans with less than 6 CFM's are quiet compared to fans with over 10 CFM's.

User avatar
danmanners
Member
 
Posts: 20
Joined: Tue Sep 01, 2015 2:53 pm
Location: Raleigh, NC
Has thanked: 1 time
Been thanked: 17 times

Re: WS-12-250 - Fan Replacement

Fri Jan 26, 2018 11:19 am

Dave wrote:Also, as a note on your fan replacement...the fan you chose will be fine for a climate controlled office, but possibly not (depending on install location, etc) for the real non-environmentally controlled WISP environment.

Your replacement fan is indeed much quieter, but can also only push 5.9 CFM's of air, while our production fan can push 10.8 CFM's. Basically, most fans with less than 6 CFM's are quiet compared to fans with over 10 CFM's.


:agree:

If you've read this far, don't do this mod in a real non-environmentally controlled environment. I did this BECAUSE it's in a climate controlled office.

wirelessblue
Member
 
Posts: 34
Joined: Wed Apr 22, 2015 5:50 pm
Has thanked: 9 times
Been thanked: 1 time

Re: WS-12-250 - Fan Replacement

Mon Jul 23, 2018 9:52 pm

Out of curiosity, would a Noctua 40mm fan also work the same? Would it need the same modification to the wires as the linked set of pictures shows? I have a similar situation where I want a Netonix switch next to my desk in a studio environment but the stock fan is too noisy.

User avatar
lligetfa
Associate
Associate
 
Posts: 1191
Joined: Sun Aug 03, 2014 12:12 pm
Location: Fort Frances Ont. Canada
Has thanked: 307 times
Been thanked: 381 times

Re: WS-12-250 - Fan Replacement

Sun Jan 27, 2019 12:34 pm

@danmanners, have you upgraded to rc12 on this modded switch and if so how well does the new fan profile work?

Return to General Discussion