Has anyone tested to see if Trango licensed can be powered by the switch??
Tom Fadgen
coastinet.com
Trango Compatibility
-
sirhc - Employee
- Posts: 7421
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1609 times
- Been thanked: 1326 times
Re: Trango Compatibility
Please post what pins they use for power and watts required I can tell you.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Re: Trango Compatibility
-48 on all pins and 48-72 watts depending on sub band.
-
sirhc - Employee
- Posts: 7421
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1609 times
- Been thanked: 1326 times
Re: Trango Compatibility
tfadgen wrote:-48 on all pins and 48-72 watts depending on sub band.
Which pins are positive and which pins are negative?
The current load will probably be OK if 48 watts is the average load with spikes to 72 watts.
Here is our pin out which is the same as 802.3af/at
CLICK IMAGE TO SEE FULL SIZE
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
lligetfa - Associate
- Posts: 1191
- Joined: Sun Aug 03, 2014 12:12 pm
- Location: Fort Frances Ont. Canada
- Has thanked: 307 times
- Been thanked: 381 times
Re: Trango Compatibility
I would guess that the positive ground return for the power is via the tower earthing (protection ground) and not on the ethernet cable.
-
sirhc - Employee
- Posts: 7421
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1609 times
- Been thanked: 1326 times
Re: Trango Compatibility
lligetfa wrote:I would guess that the positive ground return for the power is via the tower earthing (protection ground) and not on the ethernet cable.
I could be wrong but I doubt Trango is using Earth ground for the DC negative.
I would agree they are using all 4 pairs 2 pair for pos and 2 pair for neg, and I would "guess" they are using the standard pin outs as shown above but one would need to take an old jumper and cut one end off, strip the wires, and plug the other end into the supplied Trango brick an then use a VOM to map the pins, or...... look and see if they have them documented.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
lligetfa - Associate
- Posts: 1191
- Joined: Sun Aug 03, 2014 12:12 pm
- Location: Fort Frances Ont. Canada
- Has thanked: 307 times
- Been thanked: 381 times
Re: Trango Compatibility
sirhc wrote:I could be wrong but I doubt Trango is using Earth ground for the DC negative...
Maybe we are both wrong. I think Trango uses reverse polarity so the ground side is positive.
Anyway I quickly perused the following link http://support.trangosys.com/entries/20 ... stallation where they say "Since the PoE Requires ALL 8 conductors AND the shield which acts as the ground" but could have read too much into it. I don't know why it is so hard to find an actual pinout.
- amp
- Member
- Posts: 9
- Joined: Thu Dec 17, 2015 2:49 am
- Has thanked: 0 time
- Been thanked: 0 time
Re: Trango Compatibility
Did you guys ever figure out if trango works? I got a couple links without injectors and i don't want to power them by dc plug, much rather buy some switches.
8 posts
Page 1 of 1