I have an 8-150 that is rebooting like the switch in the thread. Is there a range of MAC addresses or serial numbers that were in the "bad batch" of switches? I have this one on a Tripplite Inverter/Charger.
Thanks,
WS-8-150-AC Constant Rebooting
- Sjones1
- Member
- Posts: 6
- Joined: Sat Feb 13, 2016 5:20 pm
- Has thanked: 0 time
- Been thanked: 0 time
- Sjones1
- Member
- Posts: 6
- Joined: Sat Feb 13, 2016 5:20 pm
- Has thanked: 0 time
- Been thanked: 0 time
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: WS-8-150-AC Constant Rebooting
Sjones1 wrote:Firmware is 1.4.1.
Well I would take it out of service
Upgrade the firmware to v1.4.9 as your firmware is over a year old
bench test it with all 8 Ethernet ports active POE active on port is optional, let it run over night, and if it still reboots RMA it.
It could be defective CAP issue which is warrantied if that is the cause
viewtopic.php?f=6&t=2591&hilit=c51+3V+CAP+rma#p18176
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
- Sjones1
- Member
- Posts: 6
- Joined: Sat Feb 13, 2016 5:20 pm
- Has thanked: 0 time
- Been thanked: 0 time
Re: WS-8-150-AC Constant Rebooting
Thank you! I'm switching it out tomorrow with another Netonix and will do the testing.
Who is online
Users browsing this forum: No registered users and 55 guests