Hey All,
We just recently started dropping these switches into production and for the past few months each site seems to be rebooting at random intervals. After some poking around, the only common theme I see is that they are all WS-26-500-DC's. All our sites use a Netonix switch and the rest don't appear to be having this problem.
Has anyone else had this problem? Any setting I may be doing incorrectly on these?
Thank you!
edit: we are using 1.4.9 firmware on all sites
WS-26-500-DC switches rebooting randomly?
-
intellipop - Member
- Posts: 46
- Joined: Tue Nov 10, 2015 11:10 pm
- Location: Salt Lake City, UT
- Has thanked: 7 times
- Been thanked: 2 times
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: WS-26-500-DC switches rebooting randomly?
How are you powering the units?
Are they hooked directly to the battery bank or are you powering it with a power supply?
Define how you are powering it.
Are they hooked directly to the battery bank or are you powering it with a power supply?
Define how you are powering it.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
intellipop - Member
- Posts: 46
- Joined: Tue Nov 10, 2015 11:10 pm
- Location: Salt Lake City, UT
- Has thanked: 7 times
- Been thanked: 2 times
Re: WS-26-500-DC switches rebooting randomly?
sirhc wrote:How are you powering the units?
Are they hooked directly to the battery bank or are you powering it with a power supply?
Define how you are powering it.
We are plugged directly into a battery with a breaker
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: WS-26-500-DC switches rebooting randomly?
Odd
I wish I could be there to help you debug it.
If you like you can RMA one and we will fully check it out, if we find something we will fix it and send it right back and see if it stops?
I wish I could be there to help you debug it.
If you like you can RMA one and we will fully check it out, if we find something we will fix it and send it right back and see if it stops?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
intellipop - Member
- Posts: 46
- Joined: Tue Nov 10, 2015 11:10 pm
- Location: Salt Lake City, UT
- Has thanked: 7 times
- Been thanked: 2 times
Re: WS-26-500-DC switches rebooting randomly?
sirhc wrote:Odd
I wish I could be there to help you debug it.
If you like you can RMA one and we will fully check it out, if we find something we will fix it and send it right back and see if it stops?
Are there any steps you might recommend to take? I'm ready to blame us since we have 3 of them doing it at different sites
If not, we can do an RMA on the main one.
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: WS-26-500-DC switches rebooting randomly?
I would RMA 1 of them and we will test the shit out of it and see what we find.
I will move it to the front of the line for you and turn it around quickly
I will move it to the front of the line for you and turn it around quickly
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
intellipop - Member
- Posts: 46
- Joined: Tue Nov 10, 2015 11:10 pm
- Location: Salt Lake City, UT
- Has thanked: 7 times
- Been thanked: 2 times
Re: WS-26-500-DC switches rebooting randomly?
sirhc wrote:I would RMA 1 of them and we will test the shit out of it and see what we find.
I will move it to the front of the line for you and turn it around quickly
Ok, I have 250 people on this site so I will need to plan a scheduled maintenance, I will get the RMA going as quickly as possible. Thank you for the help you guys are great
-
intellipop - Member
- Posts: 46
- Joined: Tue Nov 10, 2015 11:10 pm
- Location: Salt Lake City, UT
- Has thanked: 7 times
- Been thanked: 2 times
Re: WS-26-500-DC switches rebooting randomly?
So we just deployed another one in our office, and it looks like it's been nearly rebooting nightly, we have a LAG going to another 26 port on the roof and it's not rebooted in 9 days, since we deployed it... Both are 1.4.9, should I just RMA the office one that's nearly rebooting nightly
We also just noticed the one that is in production and not rebooting (26 days uptime atm) is running Firmware Version 1.4.7rc20
We also just noticed the one that is in production and not rebooting (26 days uptime atm) is running Firmware Version 1.4.7rc20
Last edited by intellipop on Thu Feb 15, 2018 5:34 pm, edited 1 time in total.
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: WS-26-500-DC switches rebooting randomly?
intellipop wrote:So we just deployed another one in our office, and it looks like it's been nearly rebooting nightly, we have a LAG going to another 26 port on the roof and it's not rebooted in 9 days, since we deployed it... Both are 1.4.9, should I just RMA the office one that's nearly rebooting nightly
We also just noticed the one that is in production and not rebooting (26 days uptime atm) is running
Firmware Version
1.4.7rc20
Not sure what you meant by ending the post with Firmware Version 1.4.7rc20 as you say they are both v.1.4.9
If it is indeed v1.4.9 and rebooting yes please RMA, else upgrade to v1.4.9 and make sure still happening.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
intellipop - Member
- Posts: 46
- Joined: Tue Nov 10, 2015 11:10 pm
- Location: Salt Lake City, UT
- Has thanked: 7 times
- Been thanked: 2 times
Re: WS-26-500-DC switches rebooting randomly?
sirhc wrote:intellipop wrote:So we just deployed another one in our office, and it looks like it's been nearly rebooting nightly, we have a LAG going to another 26 port on the roof and it's not rebooted in 9 days, since we deployed it... Both are 1.4.9, should I just RMA the office one that's nearly rebooting nightly
We also just noticed the one that is in production and not rebooting (26 days uptime atm) is running
Firmware Version
1.4.7rc20
Not sure what you meant by ending the post with Firmware Version 1.4.7rc20 as you say they are both v.1.4.9
If it is indeed v1.4.9 and rebooting yes please RMA, else upgrade to v1.4.9 and make sure still happening.
Sorry that was a formatting goof, we have 6 in production and 5 are rebooting, the one that is not rebooting is on the older firmware - just wanted to see if this was relevant or not. We will still RMA the one thats giving us the most headaches