MIB File
- FuzzyDice
- Member
- Posts: 7
- Joined: Thu Jan 05, 2017 4:47 am
- Has thanked: 0 time
- Been thanked: 0 time
- IntL-Daniel
- Experienced Member
- Posts: 170
- Joined: Mon Nov 02, 2015 5:07 pm
- Location: Czech Republic
- Has thanked: 7 times
- Been thanked: 9 times
Re: MIB File
Is it possible to monitor memory consuption via SNMP? I cannot find value in SNMP MIB.
- s7stem-abotbyl
- Member
- Posts: 6
- Joined: Tue Nov 14, 2017 5:00 pm
- Has thanked: 2 times
- Been thanked: 0 time
Re: MIB File
Any way to put Packets per Second in the MIB file? Grabbing it via API is a painful workaround.
- alex03
- Member
- Posts: 1
- Joined: Wed Aug 15, 2018 3:04 pm
- Has thanked: 0 time
- Been thanked: 0 time
Re: Increase the on board 24V power supply capacity
There is some way to monitor the voltage input in a DC netonix through some software.? for example -The Dude-
-
sirhc - Employee
- Posts: 7415
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Increase the on board 24V power supply capacity
alex03 wrote:There is some way to monitor the voltage input in a DC netonix through some software.? for example -The Dude-
WHy would you ask this question in this thread? It's like going into the donut shop and asking how much for a can of oil.
But anyway our switches support SNMP and you can get all the info you want via SNMP.
I would upgrade to v1.5.0 or v1.5.1rc4, download our MIB file and there you go.
You can search the forum with the Search box and find out answers to many question already asked and answered.
I MOVED YOUR POST AND MINE TO A BETTER PLACE
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
Omniflux - Experienced Member
- Posts: 113
- Joined: Tue Feb 24, 2015 3:04 pm
- Has thanked: 5 times
- Been thanked: 32 times
Re: MIB File
Can we get SNMP support for the following items?
(listed in order of usefulness, for me)
Power available - for example, the WS-12-250 description says:
250 Watt POE budget when input voltage above 12V
200 Watt POE budget when input voltage above 11V
150 Watt POE budget when input voltage below 10V
An entry reporting when power to a port is turned off due to PoE Smart failing - possibly as POWER-ETHERNET-MIB::pethPsePortDetectionStatus?
POWER-ETHERNET-MIB::pethMainPsePower - value depends on 24v/48v and HV or not
POWER-ETHERNET-MIB::pethPsePortAdminEnable
EtherLike-MIB::dot3PauseTable
EtherLike-MIB::dot3StatsTable
Also, in the current MIB, the description for fanEntry references disk instead of fan
(listed in order of usefulness, for me)
Power available - for example, the WS-12-250 description says:
250 Watt POE budget when input voltage above 12V
200 Watt POE budget when input voltage above 11V
150 Watt POE budget when input voltage below 10V
An entry reporting when power to a port is turned off due to PoE Smart failing - possibly as POWER-ETHERNET-MIB::pethPsePortDetectionStatus?
POWER-ETHERNET-MIB::pethMainPsePower - value depends on 24v/48v and HV or not
POWER-ETHERNET-MIB::pethPsePortAdminEnable
EtherLike-MIB::dot3PauseTable
EtherLike-MIB::dot3StatsTable
Also, in the current MIB, the description for fanEntry references disk instead of fan
-
Omniflux - Experienced Member
- Posts: 113
- Joined: Tue Feb 24, 2015 3:04 pm
- Has thanked: 5 times
- Been thanked: 32 times
Re: MIB File
dcdcEfficiency is missing the instance subidentifier (.0). I'm running 1.5.2.
-
Omniflux - Experienced Member
- Posts: 113
- Joined: Tue Feb 24, 2015 3:04 pm
- Has thanked: 5 times
- Been thanked: 32 times
Re: MIB File
If an element is queried from a non existent table, it appears the next table is used for the reply instead of No Such Object.
This fills my NMS logfile with lines like
- Code: Select all
$ snmpget -v2c -c XXX -On 100.96.49.2 .1.3.6.1.2.1.2.2.1.6.3
.1.3.6.1.2.1.2.2.1.7.3 = INTEGER: up(1)
This fills my NMS logfile with lines like
- Code: Select all
SNMP response from host "100.96.60.2" contains variable bindings that do not match the request: sent ".1.3.6.1.2.1.2.2.1.6.10", received ".1.3.6.1.2.1.2.2.1.7.10"
-
Stephen - Employee
- Posts: 1033
- Joined: Sun Dec 24, 2017 8:56 pm
- Has thanked: 85 times
- Been thanked: 181 times
Re: MIB File
Will be doing an rc release soon with some accumulated issues. Will check this and add it to the list.
Who is online
Users browsing this forum: No registered users and 38 guests