v1.5.0rc3 and newer Bug Reports and Comments.

DOWNLOAD THE LATEST FIRMWARE HERE
IntL-Daniel
Experienced Member
 
Posts: 170
Joined: Mon Nov 02, 2015 5:07 pm
Location: Czech Republic
Has thanked: 7 times
Been thanked: 9 times

Re: v1.5.0rc3 and newer Bug Reports and Comments.

Mon Apr 30, 2018 11:45 am

I have just tried to enable SNMP on my WS-12-250-AC on 1.5.0rc3 and memory consuptipon stated to raise every second... at the state below I didi quickly reboot task from WEB UI to avoid crash...
Attachments
netonix.jpg

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.5.0rc3 and newer Bug Reports and Comments.

Mon Apr 30, 2018 12:32 pm

IntL-Daniel wrote:I have just tried to enable SNMP on my WS-12-250-AC on 1.5.0rc3 and memory consuptipon stated to raise every second... at the state below I didi quickly reboot task from WEB UI to avoid crash...


A little more information would help.

After you restarted the task did the problem come back forcing you to disable SNMP?

How often are you polling the switch with SNMP as you do not want to poll the switch every second.

Please provide more details.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
Stephen
Employee
Employee
 
Posts: 1033
Joined: Sun Dec 24, 2017 8:56 pm
Has thanked: 85 times
Been thanked: 181 times

Re: v1.5.0rc3 and newer Bug Reports and Comments.

Mon Apr 30, 2018 8:09 pm

Hello IntL-Daniel,

I tried to recreate the issue in my lab. I have PRTG Network Monitor setup to query a WS-12-250-AC every 60 seconds and activated SNMP both v1 and v2. I noticed that if I had both SNMP versions v1 and v2c active at the same time it would cause a brief spike in CPU Usage but it quickly settled back to about 20%. I allowed the system to run in these different state's for at least an hour a piece and never saw the memory spike more than 44.1MB

Could you provide us with some more details about your setup?

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

v1.5.0rc4 and newer Bug Reports and Comments.

Mon Apr 30, 2018 9:43 pm

RC4 Released 4/30/2018

v1.5.0rcX wrote:FIXED/CHANGED
- Fixed I2C service to deal with errors better to prevent reboots with WS-12-250-DC and WS-26-500-DC - RC2 & RC3
Note: The attempt to fix I2C in RC2 was a failure and caused worse issues.
It was rushed out too fast with not enough testing.
If you downloaded v1.5.0rc2 DELETE IT AND NEVER USE IT AGAIN
We spent almost a week testing the I2C in RC3 and feel we got it right this time.

- Fixed sending CDP frames tagged with VID 1 if the management VLAN is not VID 1 - RC1
- Fixed SNMP walk failing if VLANs are not in numerical order - RC1
- Fixed using hash mark in SMTP password - RC1
- Fixed using hash mark in RADIUS password - RC1
- Fixed issues with Loop Protection on SFP ports - RC1
- Fixed intermittent telemetry error on Device/Status TAB mostly seen with WS-26-500-DC - RC1
- Fixed power TAB where shutdown time set to 12 AM would immediately turn off poe on that port - RC4
- Fixed ST/RSTP bridge priority change would not update properly - RC4

ENHANCEMENTS
- Optimized code to reduce CPU utilization especially needed for the WS-26-500-DC - RC1 <= CRITICAL
- Changed watchdog to wait for Startup + Interval seconds before checking again after watchdog is triggered - RC1
- Added log entry to report if the switch rebooted due to watchdog timer - RC1
- Added lldpRemPortId, lldpRemPortIdSubtype, and lldpRemPortDesc to LLDP-MIB - RC1
- Added cdpCacheDevicePort to CISCO-CDP-MIB - RC1
- Added popover for POE enabled ports on 'Watts' column to show power usage on each pair for VH ports - RC1
- Added root bridge id to STP log message - RC1
- SNMP Contact and Location character limit increased from 26 to 255 characters - RC4

KNOWN ISSUES
- WEB UI issues when not at 100% Zoom on browser especially on VLAN TAB
- Some language templates need help - please private message Eric Stern to help
- IGMP snooping over VLANS, MSTP, and ERPS are still being developed

RC1 Released 3/19/2018
RC2 Released 3/22/2018
RC3 Released 4/3/2018
RC4 Released 4/30/2018
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

wirelessblue
Member
 
Posts: 34
Joined: Wed Apr 22, 2015 5:50 pm
Has thanked: 9 times
Been thanked: 1 time

Re: v1.5.0rc3 and newer Bug Reports and Comments.

Thu May 03, 2018 3:11 pm

In the main "Status" tab, did the Watts field get removed in 1.5.0rcX? I just upgraded a WS-8-150-AC and a WS-12-250-AC and the Watts field which was next to PoE is gone.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.5.0rc3 and newer Bug Reports and Comments.

Thu May 03, 2018 3:30 pm

wirelessblue wrote:In the main "Status" tab, did the Watts field get removed in 1.5.0rcX? I just upgraded a WS-8-150-AC and a WS-12-250-AC and the Watts field which was next to PoE is gone.



WS-8-150-AC does not have per port watts - NEVER DID
http://forum.netonix.com/viewtopic.php? ... tch#p13339
http://forum.netonix.com/viewtopic.php? ... tch#p13550

I am looking at my WS-12-250-AC and watts column is there?
watts.png
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

wirelessblue
Member
 
Posts: 34
Joined: Wed Apr 22, 2015 5:50 pm
Has thanked: 9 times
Been thanked: 1 time

Re: v1.5.0rc3 and newer Bug Reports and Comments.

Thu May 03, 2018 5:03 pm

Thanks. I missed that detail. I must not have checked the WS-12-250-AC unit properly because it's right there now that I look at it. Thank you.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

v1.5.0rc5 Released

Fri May 25, 2018 4:18 pm

v1.5.0rcX wrote:FIXED/CHANGED
- Fixed I2C service to deal with errors better to prevent reboots with WS-12-250-DC and WS-26-500-DC - RC2 & RC3
Note: The attempt to fix I2C in RC2 was a failure and caused worse issues.
It was rushed out too fast with not enough testing.
If you downloaded v1.5.0rc2 DELETE IT AND NEVER USE IT AGAIN
We spent almost a week testing the I2C in RC3 and feel we got it right this time.

- Fixed sending CDP frames tagged with VID 1 if the management VLAN is not VID 1 - RC1
- Fixed SNMP walk failing if VLANs are not in numerical order - RC1
- Fixed using hash mark in SMTP password - RC1
- Fixed using hash mark in RADIUS password - RC1
- Fixed issues with Loop Protection on SFP ports - RC1
- Fixed intermittent telemetry error on Device/Status TAB mostly seen with WS-26-500-DC - RC1
- Fixed power TAB shutdown time set to 12 AM would turn off poe on that port - RC4
- Fixed ST/RSTP bridge priority change would not update properly - RC4
- Fixed cli on WS-8-150-DC model's allowing one to set the power restart/shutoff from cli - RC5
- Fixed scheduled portbounce to no longer trigger unexpected link status change email - RC5
- Extended length for URL resource for SMTP recipient address - RC5
- Fixed SNMP broken in v1.5.0rc5 due to a build mistake - RC6
- Fixed SNMP handling longer firmware version - RC6

ENHANCEMENTS
- Optimized code to reduce CPU utilization especially needed for the WS-26-500-DC - RC1 <= CRITICAL
- Changed watchdog waits + Interval seconds before checking again after watchdog is triggered - RC1
- Added log entry to report if the switch rebooted due to watchdog timer - RC1
- Added lldpRemPortId, lldpRemPortIdSubtype, and lldpRemPortDesc to LLDP-MIB - RC1
- Added cdpCacheDevicePort to CISCO-CDP-MIB - RC1
- Added popover for POE enabled ports on 'Watts' column to show power usage on each pair for VH ports - RC1
- Added root bridge id to STP log message - RC1
- Added Low Voltage notification for DC model's to contain the threshold and the present value in the log/email - RC5
- SNMP Contact and Location character limit increased from 26 to 255 characters - RC4
- Improved ability to deal with loops while loop protection, flow control, and STP disabled to not reboot - RC5
- Added checkbox to SYSLOG Configuration called "Log Name" which appends the switch name to messages - RC6
- Added Calling-Station-Id to RADIUS attributes to allow freeradius to log ip address of client - RC6

KNOWN ISSUES
- WEB UI issues when not at 100% Zoom on browser especially on VLAN TAB
- Some language templates need help - please private message Eric Stern to help
- IGMP snooping over VLANS, MSTP, and ERPS are still being developed

RC1 Released 3/19/2018
RC2 Released 3/22/2018
RC3 Released 4/3/2018
RC4 Released 4/30/2018
RC5 Released 5/25/2018 - BROKE SNMP Confirmed 5/31/2018
RC6 Released 6/2/2018
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: v1.5.0rc3 and newer Bug Reports and Comments.

Sun May 27, 2018 8:35 pm

Could I please get some feedback on v1.5.0rc5 as I NEED to finalize this version.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
rwineteer
Member
 
Posts: 12
Joined: Wed Nov 18, 2015 11:36 am
Location: WY, CO, ID, WA, MT, NM
Has thanked: 1 time
Been thanked: 0 time

Re: v1.5.0rc3 and newer Bug Reports and Comments.

Wed May 30, 2018 3:53 pm

Installed rc5 on a WS-12-250-DC, and after the update snmp polling the device no longer works. Unit previously had rc3 with snmp working.

PreviousNext