POE Options - POE Smart - Cable Shorts

amp
Member
 
Posts: 9
Joined: Thu Dec 17, 2015 2:49 am
Has thanked: 0 time
Been thanked: 0 time

Re: POE Options - POE Smart - Cable Shorts

Thu Oct 20, 2016 5:00 am

I was moving ports from a ac netonix 12 to a dc netonix 12 and had significant external sparks off the cat5 connector(i believe, obstructed view) as well as smoke from inside. Was running normal 24v to a ubiquiti ac which is now fried. I believe the only way for that to happen is a short between positive or negative pins and shield on the cat5. Unfortunately the fluke tester was not catching it. Probably depended on the movement in the cable. The port still seems to work but in this case what smoked?

User avatar
sirhc
Employee
Employee
 
Posts: 7419
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: POE Options - POE Smart - Cable Shorts

Thu Oct 20, 2016 9:22 am

No idea but this is another reason why we say do not plug and unplug cables to live ports as this disables POE Smart which will check for cross shorts before turning power on.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
brian@nwtowers.com
Member
 
Posts: 1
Joined: Tue Dec 01, 2015 9:25 pm
Location: Portland, OR
Has thanked: 0 time
Been thanked: 0 time

Re: POE Options - POE Smart - Cable Shorts

Wed Jul 05, 2017 4:44 pm

Can you please clarify / correct the original post.

In the first section it says:

"There are 4 pairs in an Ethernet Cable:

Pair 1: Green & Green White
Pair 2: Orange & Orange White
Pair 3: Blue & Blue White
Pair 4: Brown & Brown White"

and later on under Common Questions:

"There are 4 Pairs and 8 PINs in an Ethernet Cable:

Pair 1: White Orange.(PIN 1 ) & Orange.(PIN 2) is
POSITIVE

Pair 2: White Green...(PIN 3) & Green...(PIN 6) is
NEGATIVE
Pair 3: White Blue.....(PIN 4) & Blue.....(PIN 5) is
POSITIVE

Pair 4: White Brown..(PIN 7) & Brown...(PIN 8) is
NEGATIVE"

You flop pairs 1 and 2 (Of course pair numbers change depending on T568A vs B). Would be better written if only 1 standard is used in documentation.

As mentioned in the post, p17 of the Spec Sheet is the info I needed, and clear regardless of the standard being used.

User avatar
sirhc
Employee
Employee
 
Posts: 7419
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: POE Options - POE Smart - Cable Shorts

Wed Jul 05, 2017 6:03 pm

brian@nwtowers.com wrote:Can you please clarify / correct the original post.

In the first section it says:

"There are 4 pairs in an Ethernet Cable:

Pair 1: Green & Green White
Pair 2: Orange & Orange White
Pair 3: Blue & Blue White
Pair 4: Brown & Brown White"

and later on under Common Questions:

"There are 4 Pairs and 8 PINs in an Ethernet Cable:

Pair 1: White Orange.(PIN 1 ) & Orange.(PIN 2) is
POSITIVE

Pair 2: White Green...(PIN 3) & Green...(PIN 6) is
NEGATIVE
Pair 3: White Blue.....(PIN 4) & Blue.....(PIN 5) is
POSITIVE

Pair 4: White Brown..(PIN 7) & Brown...(PIN 8) is
NEGATIVE"

You flop pairs 1 and 2 (Of course pair numbers change depending on T568A vs B). Would be better written if only 1 standard is used in documentation.

As mentioned in the post, p17 of the Spec Sheet is the info I needed, and clear regardless of the standard being used.


Yes I corrected it, should be:
Pair 1: Orange & Orange White
Pair 2: Green & Green White
Pair 3: Blue & Blue White
Pair 4: Brown & Brown White

Yes, I am using T568B as my reference.
CAT5.jpg
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

Patriots15
Member
 
Posts: 4
Joined: Wed Nov 15, 2017 3:12 pm
Has thanked: 0 time
Been thanked: 0 time

Cable Pinouts..

Wed Mar 14, 2018 5:44 pm

New to power and want to get a confirmation whether this is good logic. So we are wanting to get rid of a non managed switch at a site. I am setting up a netonix ws-8-150AC. I was going over the pinouts on a POE supply i would like to eliminate. We have a Tycon DATA/POE switch on tower being powered by a Tycon POE HP 56g. I would like to eliminate that POE and have the Netonix power the switch. By looking at the pinouts on info sheet and looking through older Netonix posts with power info and which pinouts do what, I would think that im not going to be able to accomplish what I would like to do.

Here is a link to the pinouts of POE: http://tyconsystems.com/documentation/S ... 0Sheet.pdf

User avatar
sirhc
Employee
Employee
 
Posts: 7419
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: POE Options - POE Smart - Cable Shorts

Wed Mar 14, 2018 5:54 pm

Read post 1 of this thread.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

Brow2672
Member
 
Posts: 1
Joined: Sat Jun 30, 2018 7:06 pm
Has thanked: 0 time
Been thanked: 0 time

Re: POE Options - POE Smart - Cable Shorts

Sun Jul 01, 2018 1:24 am

Did you get it figured out? I have same issue

User avatar
ste
Member
 
Posts: 84
Joined: Fri May 22, 2015 5:33 am
Location: Regensburg Germany
Has thanked: 2 times
Been thanked: 13 times

Re: POE Options - POE Smart - Cable Shorts

Wed May 05, 2021 7:51 am

Is there a DC POE-Adapter powering a WS-6-Mini ?

User avatar
sirhc
Employee
Employee
 
Posts: 7419
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: POE Options - POE Smart - Cable Shorts

Thu May 06, 2021 8:39 am

You can power a WS-6 3 different ways (pick 1)

See product description from web store below:

Can be powered by:

48VH 1.5A passive POE port from another WISP Switch.
48-54V DC POE adapter up to 2A
48-54V DC barrel connector up to 2A

Power adapter NOT included.


We sell barrel adapter or POE adapter separately.
Currently we are our of barrel adapters waiting on new shipment.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

gdhillon@velociter.net
Member
 
Posts: 1
Joined: Tue Apr 18, 2023 6:15 pm
Has thanked: 0 time
Been thanked: 0 time

Re: POE Options - POE Smart - Cable Shorts

Wed Apr 19, 2023 11:19 am

Hi,

I was looking for a Netonix Technical support email but I found this. I would really appreciate if anyone can help me here.

We are a WISP and each of our PoP locations has more than 4 Netonix switches, that power APs, BH etc.

We use Netonix WS-12-250-DC mostly. We have been facing this issue with our Bachhaul (BH) devices Aviat WTM4800 and Mimosa B11, where we have observed BH devices stop consuming any Power. The switch is still accessible through a web interface, and the device on other ports stays up and reachable.


Switch 1 - WS-12-250-DC - has 8 device using 24V .75A each , 1 Device Aviat WTM4800 use 48VH 1.5A.
Switch 2 - WS-12-250-DC - has 1 Device 24V .75A, 3 Device 1 Mimosa B11 and 2 Dragonwaves using 48VH 1.5A.

Avait consumes 62 watts and Mimosa consumes 30 watts, both devices go down sporadically. we had to reseat cables to fix this issue. we have switched ports as well but that didn't solve it.

For Mimosa B11 we switched it to using a POE injector for a while now and never got down again.

Do I need to turn OFF PS for Mimosa B11 and Aviat WTM4800 in NEtonix Configurations ??

Please help me resolve this issue or help me understand if there is any configuration issue.

Thank You

Previous