Power reporting

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
theteksolution
Member
 
Posts: 19
Joined: Mon Oct 26, 2015 7:40 pm
Location: Chatsworth, California
Has thanked: 6 times
Been thanked: 1 time

Power reporting

Tue May 22, 2018 3:08 am

We use netonix switches for power monitoring at all of our solar installations. Last night we had a site hit the low power threshold which generated hundreds of alerts throughout the night as the voltage fluctuated 24.1-24 and alerted every time. would it be easy to add a field for "voltage recovery" so that we only get 1 low voltage alert, and 1 voltage recovery alert when the system voltage passes the set value? Thx, Charles....

User avatar
scracha
Member
 
Posts: 53
Joined: Thu Sep 15, 2016 8:36 pm
Has thanked: 5 times
Been thanked: 5 times

Re: Power reporting

Sun Jun 03, 2018 1:36 am

I'd also like to request this thanks.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Power reporting

Sun Jun 03, 2018 8:58 am

scracha wrote:I'd also like to request this thanks.


Are you running v1.5.0rc6 ?

I "think" we changed something as to email alerts in v1.5.0rcX
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
theteksolution
Member
 
Posts: 19
Joined: Mon Oct 26, 2015 7:40 pm
Location: Chatsworth, California
Has thanked: 6 times
Been thanked: 1 time

Re: Power reporting

Wed Aug 08, 2018 2:10 am

Running 1.5.0 on ours.

flameproof
Member
 
Posts: 22
Joined: Thu Sep 24, 2015 6:04 am
Has thanked: 0 time
Been thanked: 1 time

Re: Power reporting

Wed Aug 08, 2018 4:18 am

I add to this request, we are running 1.4.9 on some switches and 1.5.0 in others, same issue, emails keep coming very fast.

User avatar
theteksolution
Member
 
Posts: 19
Joined: Mon Oct 26, 2015 7:40 pm
Location: Chatsworth, California
Has thanked: 6 times
Been thanked: 1 time

Re: Power reporting

Wed Sep 26, 2018 5:06 am

More power issues, tons of alerts. We have these sent to text via email, so getting 100 of these is pretty frustrating. Any word on a fix?

User avatar
Stephen
Employee
Employee
 
Posts: 1033
Joined: Sun Dec 24, 2017 8:56 pm
Has thanked: 85 times
Been thanked: 181 times

Re: Power reporting

Wed Sep 26, 2018 12:58 pm

theteksolution wrote:We use netonix switches for power monitoring at all of our solar installations. Last night we had a site hit the low power threshold which generated hundreds of alerts throughout the night as the voltage fluctuated 24.1-24 and alerted every time. would it be easy to add a field for "voltage recovery" so that we only get 1 low voltage alert, and 1 voltage recovery alert when the system voltage passes the set value? Thx, Charles....



OK so it's important that I understand what you want exactly and we discuss it before I add this in. So to re-iterate, what you want is another input box were you can set the voltage recovery box so even if the voltage crosses the voltage warning thresholds several times it will not send an alert unless it has already past the voltage recovery correct?

Or a more specific example, in this case, if the hypothetical voltage recovery is set to 25V, since it only fluctuates between 24.1 and 24 you won't see more than one email?

User avatar
Stephen
Employee
Employee
 
Posts: 1033
Joined: Sun Dec 24, 2017 8:56 pm
Has thanked: 85 times
Been thanked: 181 times

Re: Power reporting

Mon Oct 01, 2018 4:42 pm

Hey everyone,

1.5.1rc7 is out. It should help prevent the warning voltage emails from being so hectic.

viewtopic.php?f=17&t=240&p=848#p848

User avatar
theteksolution
Member
 
Posts: 19
Joined: Mon Oct 26, 2015 7:40 pm
Location: Chatsworth, California
Has thanked: 6 times
Been thanked: 1 time

Re: Power reporting

Wed Dec 05, 2018 1:16 am

Will try the RC version. Basically we just want to be able to have 2 fields, one for low voltage, another for recovery so we know that its charging. Also, say the low voltage point is 12 volts. If the voltage fluctuates between 12 and 12.1 we will get (currently on older firmware, have yet to test the RC version) a lot of alerts. Hundreds sometimes.

User avatar
theteksolution
Member
 
Posts: 19
Joined: Mon Oct 26, 2015 7:40 pm
Location: Chatsworth, California
Has thanked: 6 times
Been thanked: 1 time

Re: Power reporting

Wed May 22, 2019 8:15 pm

Stephen wrote:Hey everyone,

1.5.1rc7 is out. It should help prevent the warning voltage emails from being so hectic.

viewtopic.php?f=17&t=240&p=848#p848



Running 1.5.2 and now that we are hitting cloudy season waking up to 250 low voltage alerts from one single site as voltage goes from 23.5 to 23.6. Please help! Thx, Charles...