Hi all
I have a WS-250-DC and when I enable the POE on a port it immediately shows that there is wattage consumption on the port
without any device connected.
As per the attached image I have turned on POE on P1 ,2, 5, 6 and although there is no devices connected to any of the port
it indicates a wattage overload in the region of 298W.
This must be a bug in the software? Can anyone suggest a possible fix or is an RMA the only option
Wattage overload without any connection
- justfine99
- Member
- Posts: 3
- Joined: Tue Feb 28, 2017 1:56 am
- Has thanked: 0 time
- Been thanked: 0 time
-
Stephen - Employee
- Posts: 1033
- Joined: Sun Dec 24, 2017 8:56 pm
- Has thanked: 85 times
- Been thanked: 181 times
Re: Wattage overload without any connection
What version of the software are you running?
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Wattage overload without any connection
This is possibly a damaged current sensor(s)?
I would RMA it.
I would RMA it.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
- justfine99
- Member
- Posts: 3
- Joined: Tue Feb 28, 2017 1:56 am
- Has thanked: 0 time
- Been thanked: 0 time
Re: Wattage overload without any connection
Hi All
It is running the latest firmware and I have reloaded the firmware again just to make sure, still the same issue, therefor I assume it
has to be damaged current sensor
It is running the latest firmware and I have reloaded the firmware again just to make sure, still the same issue, therefor I assume it
has to be damaged current sensor
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Wattage overload without any connection
Most common cause of current sensor damage and the cause of 99% of WISP equipment damage is ground current.
I would add 2 NEW ground rods to electrical service ground rods and clean and corrosion on the connections.
Make sure electrical service ground rods are bonded to tower ground rods with #2 wire.
99% of all WISP equipment damage is from ground current (I own a WISP)
Another common cause for damage is a shorted cable or incorrect POE option applied to device.
Here are some good posts on grounding:
http://forum.netonix.com/viewtopic.php? ... 279#p19279
http://forum.netonix.com/viewtopic.php?f=30&t=1816
http://forum.netonix.com/viewtopic.php?f=30&t=188
http://forum.netonix.com/viewtopic.php? ... =30#p13447
http://forum.netonix.com/viewtopic.php?f=30&t=1429
I would add 2 NEW ground rods to electrical service ground rods and clean and corrosion on the connections.
Make sure electrical service ground rods are bonded to tower ground rods with #2 wire.
99% of all WISP equipment damage is from ground current (I own a WISP)
Another common cause for damage is a shorted cable or incorrect POE option applied to device.
Here are some good posts on grounding:
http://forum.netonix.com/viewtopic.php? ... 279#p19279
http://forum.netonix.com/viewtopic.php?f=30&t=1816
http://forum.netonix.com/viewtopic.php?f=30&t=188
http://forum.netonix.com/viewtopic.php? ... =30#p13447
http://forum.netonix.com/viewtopic.php?f=30&t=1429
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.