WS-26-500-DC on 1.5.0 rebooted - thoughts?

DOWNLOAD THE LATEST FIRMWARE HERE
michaelcrapse
Member
 
Posts: 1
Joined: Tue Oct 10, 2017 1:56 am
Has thanked: 0 time
Been thanked: 0 time

Re: WS-26-500-DC on 1.5.0 rebooted - thoughts?

Wed Nov 28, 2018 11:31 pm

We have this exact same issue(Nov 28 20:08:50 10.0.0.252 sysinit: Error: Write failed
Nov 28 20:08:51 10.0.0.252 sysinit: Error: Write failed
Nov 28 20:08:52 10.0.0.252 sysinit: Error: Read failed
Nov 28 20:08:53 10.0.0.252 sysinit: Error: Read failed)
, exact same model(WS-26-500-DC)
on exact same firmware(1.5.0)

Right off of the battery bank. Goes down once or twice a day, this was right back from RMA, replaced the temporary 12 port which chugged along for several months. Now we'll have to drop the 12 port back in until we get this figured out.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-26-500-DC on 1.5.0 rebooted - thoughts?

Thu Nov 29, 2018 1:49 am

What was the RMA # so I can see what it was in for and what we found.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

Previous
Return to Hardware and software issues

Who is online