Ground Lug on new switches

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
dray
Member
 
Posts: 18
Joined: Sun Oct 04, 2015 12:11 pm
Location: Las Vegas, NV
Has thanked: 0 time
Been thanked: 2 times

Ground Lug on new switches

Fri Jun 28, 2019 11:30 am

I just lost a switch after a storm and after closer inspection, I noticed the ground lug was painted over.

Looking at older switches the ground lug is clean.



OLDER
photo_2019-06-28_10-27-08.jpg


NEWER
photo_2019-06-28_10-26-59.jpg

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Ground Lug on new switches

Fri Jun 28, 2019 12:48 pm

It does not matter as the screw is conductive so the lug or wire wrap would get electrical contact from the screw head and the screw is conductive and the screw threads are bare..

Just because you have a ground wire connected does not mean you are lightening or more accurately based on what we see on RMAs ground current damage.

95%+ of RMA damaged units we see is GROUND CURRENT not electrical surge damage it just so happens ground current occurs more commonly during storms.

https://forum.netonix.com/viewtopic.php?f=17&t=5495&p=29607&hilit=+ground+current#p29602
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

ahteran
Member
 
Posts: 19
Joined: Sat Jun 30, 2018 5:51 am
Has thanked: 0 time
Been thanked: 1 time

Re: Ground Lug on new switches

Fri Jun 28, 2019 3:18 pm

dray wrote:I just lost a switch after a storm and after closer inspection, I noticed the ground lug was painted over.

Looking at older switches the ground lug is clean.



OLDER
The attachment photo_2019-06-28_10-27-08.jpg is no longer available


NEWER
The attachment photo_2019-06-28_10-26-59.jpg is no longer available


WS6 Low Ohm Ground mod
please see the picture
Attachments
IMG_20190420_131418-min.jpg
WS6 Low Ohm Ground mod

User avatar
dray
Member
 
Posts: 18
Joined: Sun Oct 04, 2015 12:11 pm
Location: Las Vegas, NV
Has thanked: 0 time
Been thanked: 2 times

Re: Ground Lug on new switches

Fri Jun 28, 2019 3:42 pm

Looking at the older screws and new screws, they look like the have more of a coating on them also. I just tested with a multimeter and there is no connectivity through the black paint on the lug, and poor to no connectivity through different parts of the screw. Touching the silver threads inside resulted in good contact.



photo_2019-06-28_14-36-52.jpg

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Ground Lug on new switches

Fri Jun 28, 2019 3:59 pm

They are black anodized screws, they are completely conductive. I just tested them again to make sure I am not insane.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
dray
Member
 
Posts: 18
Joined: Sun Oct 04, 2015 12:11 pm
Location: Las Vegas, NV
Has thanked: 0 time
Been thanked: 2 times

Re: Ground Lug on new switches

Fri Jun 28, 2019 5:05 pm

Chris,

Not arguing with you, just FYI just in case they changed something on you that you are not aware of.

New screws are different. Checking the bottom of the heads where the contact would be made, older ones are 0 ohms. New ones have ohms all over the place. They are darker and the coating or whatever it is, is thicker.

I would suggest everyone clean these contact points with a Dremel, or do the mod above.

photo_2019-06-28_15-57-44.jpg

Return to Hardware and software issues