FCS / CRC errors

User avatar
Omniflux
Experienced Member
 
Posts: 113
Joined: Tue Feb 24, 2015 3:04 pm
Has thanked: 5 times
Been thanked: 32 times

Re: FCS / CRC errors

Mon May 11, 2020 9:46 am

After more testing, it looks like the new fans are not the issue. I swapped fans between some new and old units and the issue still occurs only on the new units.

If I power either the Mikrotik or the Prism with an external power supply things are good.

If I have power on the Prism port, but remove power from the line and then power the radio externally, things are good.
Netonix 24V PoE -> patch cable -> PoE splitter -> patch cable -> UBNT PoE injector -> patch cable -> Prism
Netonix 48V PoE -> patch cable -> Mikrotik

The opposite if not true, the issue still occurs if I connect it this way.
Netonix 24V PoE -> patch cable -> Prism
Netonix 48V PoE -> patch cable -> PoE splitter -> patch cable -> Mikrotik -> DC Jack power

I tried this both using the power from the PoE splitter (Thanks @sakita) and from the power supply the Mikrotik ships with, it did not make a difference.

The switch reports CRC errors, and the Mikrotik reports FCS errors.

Any more ideas?

User avatar
Omniflux
Experienced Member
 
Posts: 113
Joined: Tue Feb 24, 2015 3:04 pm
Has thanked: 5 times
Been thanked: 32 times

Re: FCS / CRC errors

Mon Aug 03, 2020 6:51 pm

I swapped the power board between a new and old unit, and the issue remained with the new unit, so I now know that "Switch PCB=REV E" does not exhibit this problem, but "Switch PCB=REV J" does.

I don't think there is any way to retrieve the PCB revision electronically, so I don't think I can narrow it down further without opening lots of in use switches.

Previous
Return to General Discussion

Who is online

Users browsing this forum: No registered users and 58 guests