WS3-14-600-AC not passing management Vlan and tripping OCP

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: WS3-14-600-AC not passing management Vlan and tripping O

Fri Jan 08, 2021 4:32 pm

seems we have a problem with OCP...we will investigate its cause & report back to everyone...sorry & thanks.

josh@visiontechllc.net
Member
 
Posts: 8
Joined: Sat Dec 19, 2015 12:24 am
Has thanked: 2 times
Been thanked: 2 times

Re: WS3-14-600-AC not passing management Vlan and tripping O

Thu Jan 14, 2021 12:15 pm

I am also having problems with OCP on an Aviat Radio. Runs at 105 to 110 Watts on a WS-12-250-DC and have had no problems with it.

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: WS3-14-600-AC not passing management Vlan and tripping O

Mon Mar 15, 2021 5:41 pm

Sorry to say the OCP issue relates to some incorrect component values used for the first small production run.

Chris has replacement boards in-house now & he will be reaching out to people to send replacement boards.

I have also modified out production test plan to now test for the OCP function, along with doing a 100% manual test
of the first assembled board for each production batch to catch this in the future.

Going forward, all boards with a Rev D configuration have the correct components.

User avatar
Stephen
Employee
Employee
 
Posts: 1033
Joined: Sun Dec 24, 2017 8:56 pm
Has thanked: 85 times
Been thanked: 181 times

Re: WS3-14-600-AC not passing management Vlan and tripping O

Mon Mar 15, 2021 10:16 pm

Following up on what Dave mentioned above about the Rev D board and OCP corrections.

Anyone wanting to get the replacement please take a look at this post.

Previous
Return to Hardware and software issues

Who is online

Users browsing this forum: No registered users and 73 guests