Fiber with integrated DC...

Sun Mar 01, 2015 7:15 pm

I have a rather unusual site in that I want to stick a second mast up - around 450 meters away. So too far for standard ethernet and too far for running AC reliably.. I was rather interested in the fibre+DC cable bundle you were suggesting - presumably with the DC version of the new switch..

What kind of distance are we talking? I'm guessing probably not 450 meters, but I can live in hope.

---* Bill

User avatar
sirhc
Employee
Employee
 
Posts: 7415
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Fiber with integrated DC...

Sun Mar 01, 2015 7:39 pm

I think you are referring to the TOWER Switch?

With the TOWER Switch you are limited only by the voltage/current drop which the unit adjusts/trims voltage to compensate but 450 meters should be OK depending on power needs at the far side. At that distance you may not have as much current available to fully load the switch down.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
rebelwireless
Experienced Member
 
Posts: 607
Joined: Mon Sep 01, 2014 1:46 pm
Has thanked: 31 times
Been thanked: 136 times

Re: Fiber with integrated DC...

Tue Mar 03, 2015 11:18 am

what gauge is the copper proposed for the fiber+power integrated line? This is well understood, we can calculate the drops and maximums. my gut says that at that kind of distance you would want a large gauge power wire pair anyway.

User avatar
sirhc
Employee
Employee
 
Posts: 7415
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Fiber with integrated DC...

Tue Mar 03, 2015 11:50 am

rebelwireless wrote:what gauge is the copper proposed for the fiber+power integrated line? This is well understood, we can calculate the drops and maximums. my gut says that at that kind of distance you would want a large gauge power wire pair anyway.


Actually you do better with multiple smaller gauge wires than 1 large copper gauge. We are "looking" at using (6) 12 AWG stranded for DC power and then another wire(s) for earth ground.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
amishgenius
Associate
Associate
 
Posts: 102
Joined: Fri Apr 11, 2014 3:39 pm
Has thanked: 44 times
Been thanked: 45 times

Re: Fiber with integrated DC...

Sun Mar 08, 2015 10:50 am

12 g sounds good. I currently run 14 gauge 2 pair for 600 ft tower. A little more wouldn't hurt