Management stopped working on WS-6-MINI
Hi, one of MINIs had stopped responding on management IP. Nothing changed just suddenly stopped responding this morning. Everything is working (PoE, all vlans passing data) just management isn't responding. Is there any way to revive management (e.g. mac-telnet or something else) or powercycle is only way? Thanks.
-
sirhc - Employee
- Posts: 7415
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Management stopped working on WS-6-MINI
Are you saying you can not PING it or web browser is not connecting?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
- JOFO
- Member
- Posts: 6
- Joined: Fri Mar 03, 2017 11:18 am
- Has thanked: 0 time
- Been thanked: 0 time
Re: Management stopped working on WS-6-MINI
Yes, everything's working. Also another devices on management vlan behind the switch. Only device itself isn't responding to ping, ssh or web. It's like switch has lost its ip.
-
sirhc - Employee
- Posts: 7415
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Management stopped working on WS-6-MINI
JOFO wrote:Yes, everything's working. Also another devices on management vlan behind the switch. Only device itself isn't responding to ping, ssh or web. It's like switch has lost its ip.
Then your only option is to reboot it
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
- JOFO
- Member
- Posts: 6
- Joined: Fri Mar 03, 2017 11:18 am
- Has thanked: 0 time
- Been thanked: 0 time
Re: Management stopped working on WS-6-MINI
I was afraid that only option is to interrupt network traffic for few minutes.
- JOFO
- Member
- Posts: 6
- Joined: Fri Mar 03, 2017 11:18 am
- Has thanked: 0 time
- Been thanked: 0 time
Re: Management stopped working on WS-6-MINI
So switch had cut off one port and thus connected device was unreachable. So I managed to get it and powercycled switch. After powercycle switch is completely unresponsive. No Link is established on any port and only power led is lit. Reset doesn't work either. What could be the cause? Could you get me some hint which component could be issue? Switch is out of waranty but I'm electrician so repair shouldn't be problem for me. :) I've inspected board by eye but doesn't seem to have any sign of burn component or so.
-
sirhc - Employee
- Posts: 7415
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: Management stopped working on WS-6-MINI
Sorry, could me many different things.
I wish I could be more helpful.
I wish I could be more helpful.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
- JOFO
- Member
- Posts: 6
- Joined: Fri Mar 03, 2017 11:18 am
- Has thanked: 0 time
- Been thanked: 0 time
Re: Management stopped working on WS-6-MINI
Has WS-6-MINI serial console pins somewhere on board? I could check if there's any output on power up.
- JOFO
- Member
- Posts: 6
- Joined: Fri Mar 03, 2017 11:18 am
- Has thanked: 0 time
- Been thanked: 0 time
Re: Management stopped working on WS-6-MINI
sirhc wrote:Sorry, could me many different things.
I wish I could be more helpful.
Never mind.. I'll use it for spare parts. Just recovered another switch with blown transformer on 1st port. ;-)