WS-12-250A, hardware/firmware issues

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-12-250A, hardware/firmware issues

Mon Apr 06, 2015 4:29 pm

For the console port to "vomit" as youre indicating but yet the switch does boot and Linux "must" be loading as you can ping it , get the login page, and you get the SSH screen that would indicate that the serial interface is bad as Linux MUST be loading properly but we use the serial interface/console at the end of the line to program the MAC, Model and such so the serial interface did work at that time so it would have had to gone bad sitting?

As the switch is first booting that is Redboot which we did not customize the Redboot loader which is outputting to the console port at the initial boot?

Now I suppose it is possible that a lose screw rattling around in the chassis might have damaged the board knocking off a resistor or something?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-12-250A, hardware/firmware issues

Mon Apr 06, 2015 4:34 pm

The Linux Partition must be fine as it loads, but you can not login which would indicate that config is corrupted which is on another partition?

The weird thing here is the console port "vomiting" as you describe it.

Please verify that your console cable and emulator settings are all correct, I am not insinuating you're making a mistake but it just seems weird that the console port is behaving like this, make no sense?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
josh
Associate
Associate
 
Posts: 109
Joined: Thu Apr 17, 2014 9:29 pm
Location: USA
Has thanked: 69 times
Been thanked: 31 times

Re: WS-12-250A, hardware/firmware issues

Mon Apr 06, 2015 4:46 pm

sirhc wrote:Now when you do the 20 second default button while powering it on you did let it set for about 4 minutes before doing anything with the switch?

It takes about 4 minutes for the switch to reformat the jffs2 partition, if you disturb it during this period it will corrupt the flash partition where the config reside and could act like this.

It is very important to let it sit for that 4 minute +/- period.


Chris, I have done it 3 times now. It has now been sitting here for ~30m after a reboot. It looks like it's stuck in some kind of boot loop, but I can't confirm because I can't read the console output. :(

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-12-250A, hardware/firmware issues

Mon Apr 06, 2015 4:54 pm

Well if the console port is non functional then the recovery from the secondary partition is not possible.

Guess we are going to have to RMA this one then, sorry.

Please email the MAC address to chris@netonix.com and I will issue an official RAM number but since I know I have issued 7 others it will be NRMA0008

Please box it back up in the original box and return it to us at:

Netonix
Att: RMA - NRMA0008
154 Earland Drive
Building 5C
New Holland, PA 17557
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-12-250A, hardware/firmware issues

Mon Apr 06, 2015 4:56 pm

If it is in a boot loop then you are seeing the constant pings stop and then restart again?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
josh
Associate
Associate
 
Posts: 109
Joined: Thu Apr 17, 2014 9:29 pm
Location: USA
Has thanked: 69 times
Been thanked: 31 times

Re: WS-12-250A, hardware/firmware issues

Mon Apr 06, 2015 5:06 pm

Chris,

I went through 3 cisco style console cables, 1 null modem adapter, 3 gender changers, and finally found something that worked :)

I also found why I was seeing a CONSTANT stream of data - one of the gender changers I was using was BROKEN and was constantly sending data to the terminal, just a 0:21; over and over and over.

I was able to reset the login information and get into the switch, HOWEVER... I would love to know how this happened?

Again, originally on 1.1.1
Upgraded to 1.1.8
used the GUI to "reset to defaults"
then I couldn't log in... i'm going to try and "reproduce" this again

User avatar
josh
Associate
Associate
 
Posts: 109
Joined: Thu Apr 17, 2014 9:29 pm
Location: USA
Has thanked: 69 times
Been thanked: 31 times

Re: WS-12-250A, hardware/firmware issues

Mon Apr 06, 2015 5:08 pm

EDIT:

So, anytime I reset to defaults from the GUI, it broke my password.

HOWEVER, I just reflashed 1.1.8 for a second time, and now resetting to defaults WORKS.

I don't know how this switch got into this state with the two simple steps I was in, but I'm glad that it DOESN'T SEEM TO BE A HARDWARE OR SOFTWARE BUG, SIMPLY A FLUKE.

I will TRY to recreate this on one of my other NIB switches, and will update this thread with further info.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-12-250A, hardware/firmware issues

Mon Apr 06, 2015 5:12 pm

josh wrote:CHRIS - I can confirm.

I am on 1.1.8 right now.

Any time I "Reset to Defaults" from the GUI, it "b0rks" my password and I have to use the CLI to fix it. I was just able to reproduce this. Looks like a BUG!

Squash it! :D


So your saying if you have v1.1.8 and do a UI factory default this happens? Let me go try this cause I am sure I have tested this.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: WS-12-250A, hardware/firmware issues

Mon Apr 06, 2015 5:16 pm

I just did a UI factory default and was able to login with Username "admin" Password "admin"??

I will down grade to v1.1.1 then upgrade to v1.1.8 and factory default that?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
josh
Associate
Associate
 
Posts: 109
Joined: Thu Apr 17, 2014 9:29 pm
Location: USA
Has thanked: 69 times
Been thanked: 31 times

Re: WS-12-250A, hardware/firmware issues

Mon Apr 06, 2015 5:19 pm

(See my above update)

PreviousNext
Return to Hardware and software issues

Who is online