I just put in a new WS-12-250-AC and on the uplink port I put in a Mikrotik 1G SFP. It links and passes traffic however I am constantly getting RX Oversize Errors. A couple hundred a second. The port on my Mikrotik router shows no errors.
What could be going on?
URGENT: WS-12-250-AC SFP Issue
-
sirhc - Employee
- Posts: 7415
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: URGENT: WS-12-250-AC SFP Issue
With the limited information you are providing me I would say that your MTU on the Switch is set too small.
Rx Oversize errors are from a packet larger than the MTU is set to.
What is the MTU set at on the Router port?
Are you using VLAN or VLAN withing VALAN Tagging?
Rx Oversize errors are from a packet larger than the MTU is set to.
What is the MTU set at on the Router port?
Are you using VLAN or VLAN withing VALAN Tagging?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
-
sbyrd - Experienced Member
- Posts: 236
- Joined: Fri Apr 10, 2015 6:16 pm
- Has thanked: 16 times
- Been thanked: 26 times
Re: URGENT: WS-12-250-AC SFP Issue
Thanks for your help. I upped the MTU on the switch per your suggestion and have not seen any more RX Oversize errors.