Running firmware 1.3.3rc5.
On my WS-8-250-DC, my uplink port became disabled (in the past, POE smart disabled the port), so I lost remote communication. I thought it might be low battery issue, but upon making the trek up the mountain, I noticed the other two ports powering equipment were working fine. I powered off the Netonix and moved my uplink port to one of the ports that was still being powered. I reconnected power and received remote access again.
What do I do so this doesn't happen? If I set a ping watchdog, then the port would unpower the port for 5 seconds and repower and hopefully restore access. But if POE smart has already disabled power on the port, this wouldn't help. Do I turn off POE smart?
Or what other scenario would have turned power off on the port?
POE smart disables working port?
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: POE smart disables working port?
mtngoat wrote:Running firmware 1.3.3rc5.
On my WS-8-250-DC, my uplink port became disabled (in the past, POE smart disabled the port), so I lost remote communication. I thought it might be low battery issue, but upon making the trek up the mountain, I noticed the other two ports powering equipment were working fine. I powered off the Netonix and moved my uplink port to one of the ports that was still being powered. I reconnected power and received remote access again.
What do I do so this doesn't happen? If I set a ping watchdog, then the port would unpower the port for 5 seconds and repower and hopefully restore access. But if POE smart has already disabled power on the port, this wouldn't help. Do I turn off POE smart?
Or what other scenario would have turned power off on the port?
I am not quite following your post, if I remove the text in red I can follow this below;
You lost your uplink port
You went to site and backhaul port powered OFF.
At this point did you check the LOG to see why the port was powered OFF? <- IMPORTANT TO DO
Are you saying that ping watchdog rebooted a port then POE Smart disabled the port?
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Re: POE smart disables working port?
I lost my backhaul port.
Went to site and unpowered and repowered after moving cables. I didn't take laptop, so I didn't see logs. I will enable syslog for future logging.
I didn't have ping watchdog enabled. I was just wondering if the port gets powered off, would ping watchdog bring it back online.
I will report back if it happens again and I have the log of what happened.
Went to site and unpowered and repowered after moving cables. I didn't take laptop, so I didn't see logs. I will enable syslog for future logging.
I didn't have ping watchdog enabled. I was just wondering if the port gets powered off, would ping watchdog bring it back online.
I will report back if it happens again and I have the log of what happened.
-
sirhc - Employee
- Posts: 7416
- Joined: Tue Apr 08, 2014 3:48 pm
- Location: Lancaster, PA
- Has thanked: 1608 times
- Been thanked: 1325 times
Re: POE smart disables working port?
mtngoat wrote:I lost my backhaul port.
Went to site and unpowered and repowered after moving cables. I didn't take laptop, so I didn't see logs. I will enable syslog for future logging.
I didn't have ping watchdog enabled. I was just wondering if the port gets powered off, would ping watchdog bring it back online.
I will report back if it happens again and I have the log of what happened.
POE Smart does not turn POE off once it is ON.
POE Smart "only" checks the cables for a cross short when you save/apply POE to a port and also on a cold reboot of the switch POE Smart will check for cross shorts.
Once a port is up and running it will NOT turn the POE off. AT this point POE Smart is not even running it only runs when you enable POE on a port or during boot.
This is some place where you really need to check the switch LOG to see what happened. Who knows maybe someone hacked into your switch and turned POE OFF which would have shown up in the LOG and from what IP address.
But no, if POE smart turned POE OFF during a cold boot or on a port turn up a ping watchdog would not turn it back on because there is a cross short.
I think you are blaming this on POE Smart and there is no way it had anything to do with it from what you describe. - NEED TO LOOK AT LOGS NEXT TIME
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.
Re: POE smart disables working port?
Thanks for the insight. I will do more research next time before posting.
5 posts
Page 1 of 1
Who is online
Users browsing this forum: No registered users and 39 guests